Siemens SCALANCE XR524-8C Operating Instructions Manual page 14

Scalance xr-500 series. simatic net. industrial ethernet switches
Hide thumbs Also See for SCALANCE XR524-8C:
Table of Contents

Advertisement

Safety notes
2.1 Security recommendations
Interfaces security
● Disable unused interfaces.
● Use IEEE 802.1X for interface authentication.
● Use the function "Locked Ports" to block interfaces for unknown nodes.
● Use the configuration options of the interfaces, e.g. the "Edge Type".
● Configure the receive ports so that they discard all untagged frames ("Tagged Frames
Only").
Available protocols
The following list provides you with an overview of the open protocol ports.
The table includes the following columns:
● Protocol
● Port
● Port status
– Open
– Open (when configured)
● Factory setting
– Open
– Closed
● Authentication
Specifies whether or not the protocol is authenticated.
● Encryption
Specifies whether or not the transfer is encrypted.
Protocol
Port number
TELNET
TCP/23
SSH
TCP/22
HTTP
TCP/80
HTTPS
TCP/443
14
The port is always open and cannot be closed.
The port is open if it has been configured.
The factory setting of the port is "Open".
The factory setting of the port is "Closed".
Port status
Open (when config-
ured)
Open (when config-
ured)
Open (when config-
ured)
Open (when config-
ured)
Default status of the
Authentication
port
Open
Yes
Open
Yes
Open
Yes
Open
Yes
Operating Instructions, 05/2017, A5E03275845-11
Encryption
No
Yes
No
Yes
SCALANCE XR-500

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents