Mercury 2 & Intuitive Mercury EPR Stepper Installation Guide
Number
Parameter
P-25
Log Alarm Delay
P-26
Log UT Alarm
P-27
Log OT Alarm
P-28
Monitor OT Alarm
P-40
Defrost Mode
P-41
Defrost Start
P-42
Defrosts per Day
P-43
No Defrost Time
P-44
Def Terminate Temp.
P-45
Def Min Time
P-46
Def Max Time
P-47
Drain Down
P-48
Recovery Time
P-89
Pump Down Time
P-86
Fan Delay mode
P-49
Fan Delay Time (Cabinets)
Fan Delay Time (Coldroom) 00:00 to 99:00
P-88
Fan Delay Temp
P-50
Fans In Defrost
P-94
Defrost Hold
P-95
Defrost Skip
P-96
Defrost Skip Time
P-38
Stepper in Defrost
P-80
Door Alarm Delay
P-81
Door Closes Valve
P-82
Door Stops Fan
P-60
Lights Mode
P-61
Sun Lights On
P-62
Sun Lights Off
P-63
Mon Lights On
P-64
Mon Lights Off
P-65
Tue Lights On
P-66
Tue Lights Off
P-67
Wed Lights On
P-68
Wed Lights Off
P-69
Thu Lights On
P-70
Thu Lights Off
P-71
Fri Lights On
P-72
Fri Lights Off
P-73
Sat Lights On
P-74
Sat Lights Off
P-58
Broadcast ID
P-59
Refrigerant
P-75
Pressure Units
P-76
Evap Offset
P-84
Glide
P-91
Trans Span
P-99
Trans Offset
dFLt
Restore defaults
* Parameters P-06, P-31, P-32, P-33 and P-35 only have an effect if "Other" is selected when configuring parameter P-30
* Transducer Span and Offset allows for the full range of the transducer to be used.
Span is the full range of the transducer
Offset is the value below zero.
Example:
Refrigerant Table
0 = None. 1 = R12. 2 = R13. 3 = R13B1. 4 = R22. 5 = R23. 6 = R32. 7 = R114. 8 = R134A. 9 = R142B. 10 = R227. 11 = R401.
12 = R401A. 13 = R401B. 14 = R402. 15 = R402A. 16 = R402B. 17 = R404A. 18 = R407A. 19 = R407B. 20 = R407C. 21 = R500
Warning
Ensure that all power is
switched off before
installing or maintaining
this product
Please Note
Range
o
o
C
(
F )
00:00 to 99:00
-49 to 60 (-56.2 to 140)
-49 to 60 (-56.2 to 140)
-49 to 60 (-56.2 to 140)
0 (Local), 1 (Remote), 2 (External)
00:00 to 23:59
0 to 8
0 to 25
-42 to 30 (-43.6 to 86)
00:00 to 99:00
00:00 to 99:00
00:00 to 24:00
00:00 to 99:00
00:00 to 99:00
0 = Time, 1 = Temp
00:00 to 99:00
-42 to 30 (-43.6 to 86)
0 (Off), 1 (On)
0 (Off), 1 (On)
0 (Off), 1 (On)
00:00 to 99:00
0 = Closed, 1 = Open
00:00 to 99:00
0 (No), 1 (Yes)
0 (No), 1 (Yes)
0 (Local), 1 (Remote), 2 (Man Off),
3 (Man On)
00:00 to 23:59
00:00 to 23:59
00:00 to 23:59
00:00 to 23:59
00:00 to 23:59
00:00 to 23:59
00:00 to 23:59
00:00 to 23:59
00:00 to 23:59
00:00 to 23:59
00:00 to 23:59
00:00 to 23:59
00:00 to 23:59
00:00 to 23:59
0 to 999
See Refrigerant Table Below
0 = Absolute 1 = Gauge
0.0 to 1.0
0.0 to 5.0
-3.4 to 180.0
-3.4 to 180.0
Danfoss AKS 33 with range: -1 bar to 12 bar
Span would be 190 (13 bar)
Offset would be -15 (-1 bar)
Step
Units
01:00
mm:ss
0.1
Deg
0.1
Deg
0.1
Deg
00:01
hh:mm
1
1
hours
0.1
Deg
01:00
mm:ss
01:00
mm:ss
00:15
mm:ss
01:00
mm:ss
01:00
mm:ss
1
01:00
mm:ss
01:00
mm:ss
0.1
Deg
01:00
mm:ss
1
01:00
mm:ss
00:01
hh:mm
00:01
hh:mm
00:01
hh:mm
00:01
hh:mm
00:01
hh:mm
00:01
hh:mm
00:01
hh:mm
00:01
hh:mm
00:01
hh:mm
00:01
hh:mm
00:01 hh:mm
00:01 hh:mm
00:01 hh:mm
00:01 hh:mm
1
-
1
-
1
-
0.1
-
0.1
Deg
0.1
Bar
0.1
Bar
Revision 1.2a
Default LT
Default HT
Type
o
o
o
o
C (
F )
C (
F )
3&4
20:00
20:00
-35 (-31)
-1 (30.2)
-12 (10.4)
6 (42.8)
20 (68)
20 (68)
Local
Local
01:00
01:00
6
6
12
12
14 (57.2)
10 (50)
05:00
05:00
24:00
24:00
01:30
01:30
30:00
30:00
00:00
00:00
0
0
00:00
00:00
03:00
03:00
-20 (-4)
0.0 (32)
On
On
Off
Off
Off
Off
12:00
12:00
0
0
20:00
20:00
No
No
No
No
Local
Local
08:00
08:00
20:00
20:00
08:00
08:00
20:00
20:00
08:00
08:00
20:00
20:00
08:00
08:00
20:00
20:00
08:00
08:00
20:00
20:00
08:00
08:00
20:00
20:00
08:00
08:00
20:00
20:00
0
0
0
0
0
0
0.0
0.0
0.0
0.0
13.8
13.8
0.0
0.0
Page 11 of 25