Floor Overlay Installation - Kolpak Walk-In Installation & Operation Manual

Table of Contents

Advertisement

Installation of overlay material is best accomplished before the refrigeration system has
been started, and before any product has been loaded. In the event that overlay must
be added at a later date, ensure that the refrigeration system has been turned off and
that the subsurface has been allowed to return to a normal working temperature.
Installing at a low temperature may not allow the adhesive/sealant to cure adequately.
 Clean and dry subsurface.
 Apply silicone to the underside of flooring overlay material.
 Begin laying first row of flooring overlay ½" away from the edge of the floor
according to the drawing and secure to the subsurface with sheet metals screws
or anchors.
 All sheets must be as flush as possible to one another.
 All sheets must be secured using a sheet metal screws or anchors every 24".
Ensure that at least one fastener is used near each corner of the overlay
material.
 Continue to follow the layout according to the drawing until all sheets are flush
and secured to the subsurface.
 Caulk all seams and edges of flooring overlay material.
 Allow 1-3 hours for the adhesive/sealant to dry prior to resuming use of the walk-
in.
www.kolpak.com
Flooring Overlay Installation
CAUTION
800-225-9916
14

Advertisement

Table of Contents
loading

Table of Contents