AEMC MN307 User Manual page 2

Advertisement

2.56"
(65 mm)
.83"
(21 mm)
ELECTRICAL SPECIFICATIONS
Nominal Range: 10A
Measurement Range: 0.1 to 12A
Transformation Ratio: Voltage output
Output Signal: 100mV/A (1V at 10A)
Accuracy and Phase Shift*:
Accuracy:
0.1 to 0.5A:  2.5% Reading ± 0.1mV
 2.5% Reading
0.5 to 1A:
 1% Reading
1 to 12A:
2.00"
(51 mm)
MN307
.73"
(18.5 mm)
Tactical
Barrier
(keep hands below
this barrier)
.1.18"
Phase Shift:
.01 to 0.1A: Not Specified
 5°
0.1 to 1A:
 3°
1 to 5A:
 2.5°
5 to 12A:
*Reference conditions: 20°C to 26°C, 20 to 75% RH,
external magnetic field <40A/m, 48 to 65Hz sine wave,
distortion factor less than 1%, no DC component, no
external current carrying conductor, test sample centered.
Load impedance > 1M.
Frequency Range: 40 to 10kHz
Limit Operating Conditions:
20A permanently to 10kHz;
Derating above 10kHz: 20A x 0.1F (in kHz)
Black
(30 mm)
Red