Virtual Switches, Page Two (Alpha-Link MADI-SX and LIVE)

Settings in bold indicate defaults. Please also refer to the notes overleaf for details regarding each setting.
LED
1
AES/EBU clock source (port 'A' only)
2
3
Clock source for 'External' selection
4
5
AES/EBU sample rate converters
(port 'A' only)
6
7
8
Unused
Option
Setting
AES/EBU In 1 & 2
AES/EBU In 3 & 4
AES/EBU In 5 & 6
AES/EBU In 7 & 8
Wordclock (MADI-SX)
MADI (LIVE)
Input 1 & 2 enabled
Input 1 & 2 bypassed
Input 3 & 4 enabled
Input 3 & 4 bypassed
Input 5 & 6 enabled
Input 5 & 6 bypassed
Input 7 & 8 enabled
Input 7 & 8 bypassed
n/a
LED States
See Note
3.
4.
5.
n/a
19