Page 2
PA2500 Introduktionssidorna består huvudsakligen av bilder. För översättning av de engelska texter som används, se respektive språksidor. The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages. Introduksjonssidene består hovedsakelig av bilder. For oversettelse av de engelske tekstene, se de respektive språksidene Les pages de présentation contiennent principalement des images.
Page 3
PA2500 PA2500 1026 / 1536 / 2026 1050 / 1560 / 2050 1026 / 1536 / 2026 90,5 min 500 1050 / 1560 / 2050 90,5 min 500 Cu ø15 min 500 min 500 Cu ø15 min 500 min 500 Fig.1 ø17,5 ø17,5...
Page 9
PA2500 PA2510E05/ PA2515E08/ PA2520E10 SUPPLY L N PE ID. pot. ACTUATOR ROOM H1 H2 N F1 F2 F3 Heating Motor/trafo...
Page 10
PA2500 PA2510E08/ PA2515E12/ PA2520E16 SUPPLY L N PE ID. pot. ACTUATOR ROOM H1 H2 N F1 F2 F3 Heating Motor/trafo...
Page 11
PA2500 PA2510W/ PA2515W PA2520W SUPPLY L N PE ID. pot. ACTUATOR ROOM H1 H2 N F1 F2 F3 Heating Motor/trafo...
Page 12
PA2500 PA2510E05YD/ PA2515E08YD SUPPLY L N PE ID. pot. ACTUATOR ROOM H1 H2 N F1 F2 F3 Heating Motor/trafo...
Page 13
PA2500 PA2520E10YD SUPPLY L N PE ID. pot. ACTUATOR ROOM H1 H2 N F1 F2 F3 Heating Motor/trafo...
Page 14
PA2500 SIReB Basic PA2500 E SIReB2 SIReRTX SIReUB1 (optional) 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReB Basic - Parallel connection SIReB2 SIReB2 SIReRTX SIReUB1 (optional) 230V~ 230V~ ROOM ROOM Pot. Pot. Unit ID Unit ID ACTUATOR SUPPLY ACTUATOR SUPPLY Wiring diagrams for SIReAC Competent and SIReAA Advanced, see manuals for SIRe.
Page 15
PA2500 SIReB Basic PA2500 W SIReB2 SD230 SIReRTx SIReUB1 (optional) ROOM 230V~ Pot. Unit ID ACTUATOR SUPPLY...
Page 16
PA2500 SIReB Basic - Parallel connection PA2500 W SIReB2 SD30 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReB2 SD30 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReB2 SD30 SIReUB1 SIReRTX (optional) 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY...
Page 17
PA2500 Output charts water PA2500 Supply water temperature:110 °C Water temperature: 110/80 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +35 °C* Type Airflow Output Return Water Pressure Output * Outlet Water Pressure position water flow drop air temp.
Page 18
0,06 PA2520W 2600 12,7 46,0 0,34 48,7 28,5 0,11 1800 39,0 0,13 30,0 0,09 ) Recommended outlet air temperature for good comfort and optimized output. ) Nominal output at given supply and return water temperature. See www.frico.se for additional calculations.
PA2500 Assembly and operating instructions General Instructions Mounting Read these instructions carefully before The air curtain unit is installed horizontally installation and use. Keep this manual for with the supply air grille facing downwards future reference. as close to the door as possible. Minimum The product may only be used as set out in distance from outlet to floor for electrically heated units is 1800 mm.
Page 21
Note that the unit shall be preceded by a Modular cables are connected to the control regulating valve, see Frico valve kit. board. See manual for SIRe. The water coil is connected on the upper side of the unit with ø15 mm smooth copper Unit with water heating pipe with a suitable coupling or soldering.
PA2500 Service, repairs and maintenance Overheating For all service, repair and maintenance first The air curtain unit with electric heater is carry out the following equipped with an overheat protector. If it is 1. Disconnect the power supply. deployed due to overheating, reset as follows: 2.
Page 23
PA2500 Trouble shooting Safety • For all installations of electrically heated If the fans are not working or do not blow properly, products should a residual current circuit check the following: breaker 300 mA for fire protection be used. • That the intake grille/filter is not dirty. •...
Page 27
Main offi ce Frico AB Tel: +46 31 336 86 00 Box 102 Fax: +46 31 26 28 25 SE-433 22 Partille mailbox@frico.se Sweden www.frico.se For latest updated information and information about your local contact: www.frico.se...