Setting Up In-Band Clients - Net Insight Nimbra One User Manual

Element manager
Table of Contents

Advertisement

Setting up In-band clients

Element Manager User's Manual Nimbra OneSerie
©2006 Net Insight AB, All rights reserved
Figure 51. In-band Servers page
Re-connect checked: if secondary path is used it will re-connect to primary.
Delete checked: deletes the checked destinations.
4.
Click on Add destination.
Figure 52. In-band Servers page
5.
Enter Destination DTM node address, Destination DSTI and select if
sourse routes should be used. Click on OK.
6.
Add the servers in the peering nodes.
An In-band client must be configured on every node in the segment, including
the nodes with the In-band server.
To set up the in-band management, keep the following information at hand:
Parameter name
Description
DSTI
Index, DTM service type instance.
Client - Client
The capacity between the clients.
connection
capacity
Tear down
Channels are torn down when they are no longer
unused
used. The times in seconds before the channels
channels after
are torn down.
0 sec = channels are never torn down
600 sec = 10 minutes which is recommended
Server DTM
The DTM host name or the address of the DLE
node
server.
Server DSTI
Index of the server. DTM Service Type Instance.
Type
Man
Man
Man
Man
Man
Control Network • 55