Cleaning the Condenser
General
Disconnect electric power to the ice machine head
section and the remote condensing unit at the electric
service switches before cleaning the condenser.
A dirty condenser restricts airflow, resulting in excessively
high operating temperatures. This reduces ice production
and shortens component life.
•
Clean the condenser at least every six months.
The condenser fins are sharp. Use care when cleaning
them.
•
Shine a flashlight through the condenser to check for
dirt between the fins.
•
Blow compressed air or rinse with water from the
inside out (opposite direction of airflow).
•
If dirt still remains call a service agent to clean the
condenser.
44
Warning
n
Warning
n
Part Number STH063 9/17