Preventative Maintenance Cleaning

This cleaning procedure can be performed between the bi-
annual cleaning and sanitizing cycles. This procedure does
not require removing the ice from the bin.
Place the toggle switch in the off position after
Step 1
ice falls from the evaporator at the end of a Harvest cycle.
Or, place the toggle switch in the off position and allow the
ice to melt off the evaporator.
Never use anything to force ice from the evaporator.
Damage may result.
Wear rubber gloves and safety goggles (and/or face
shield) when handling Ice Machine Cleaner or Sanitizer.
To start a cleaning cycle, place the toggle switch
Step 2
in the clean position. Water will flow through the water
dump valve and down the drain. Wait until the water
trough refills, then add the proper amount of ice machine
cleaner to the water trough.
KT0300 - KT0400 - KT0420
KT0500 - KT0700 - KT1000
Wait until the clean cycle is complete
Step 3
(approximately 24 minutes) then place the toggle switch in
the off position.
42
,
n
Model
KT1700
Caution
Warning
Amount of Cleaner
Part Number STH063 9/17
5 ounces (150 ml)
9 ounces (265 ml)