Selecting A Communication Mode; Installing The Rs485 Communications Cable - Huawei SUN2000-33KTL-US Quick Manual

Smart string inverter mounting bracket supplied with the sun2000; amphenol helios h4
Hide thumbs Also See for SUN2000-33KTL-US:
Table of Contents

Advertisement

Positive metal terminal
Negative metal terminal
Recommended: 12 AWG PV
cable (PV1-F)
Click
5.7

Selecting a Communication Mode

The SUN2000 supports either PLC or RS485 communication mode.
NOTE
1. If PLC is used, you do not have to connect any communications cable to the SUN2000, but
have to connect the PLC CCO module or SmartLogger2000 to the AC power cable. For detailed
operations, see the PLC CCO01A User Manual or SmartLogger2000 User Manual.
2. If RS485 is used, do not connect the PLC CCO module to the AC power cable.
5.8

Installing the RS485 Communications Cable

NOTICE
1. When routing communications cables, separate communications cables from power cables to
prevent communication from being affected by signal interference.
2. An RS485 cable can connect to either a terminal block or an RJ45 network port. It is
recommended that the RS485 cable connect to a terminal block.
Terminal Block Connection (Recommended)
Recommended: outdoor communications cable with a conductor cross-sectional area of 18 AWG
and an outer diameter range of 14 mm to 18 mm (0.55 in. to 0.71 in.)
1. Remove an appropriate length of the jacket and core wire insulation layer from the
communications cable using a wire stripper.
Ensure that the cable cannot
be removed after crimped.
Ensure that the
cables are correctly
connected and that
the voltage does not
exceed 1000 V DC.
11
Positive connector
Negative
connector
Click
Ensure that
the locking nut
is secured.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sun2000-40ktl-usSun2000-36ktl-usSun2000-33kt-us