Endress+Hauser Proline Promag L 400 Operating Instructions Manual page 152

Hart electromagnetic flowmeter
Hide thumbs Also See for Proline Promag L 400:
Table of Contents

Advertisement

Technical data
Fitted electrodes
152
Electrodes
1.4435 (304L), Alloy C22
Process connections
EN 1092-1 (DIN 2501)
• DN ≤ 300 (12"): 1.0038 (S235JRG2), 1.4301 (304), 1.4306 (304L), 1.4307 (304L)
• DN ≥ 350 (14"): 1.0038 (S235JRG2), A105
ASME B16.5
• DN ≤ 300 (12"): A105, 316L
• DN ≥ 350 (14"): A105
AWWA C207
DN 1200 to 2200 (48 to 90"): 1.0044 (S275JR), 1.0425 (316L) (P265GH), A105, A181
AS 2129
DN 350 to 1200 (14 to 48"): 1.0038 (S235JRG2), 1.0345 (P235GH), 1.0425 (316L)
(P265GH), A105, FE 410 WB
AS 4087
DN 350 to 1200 (14 to 48"): 1.0044 (S275JR), 1.0425 (316L) (P265GH), A105
Seals
In accordance with DIN EN 1514-1
Accessories
Display protection
Stainless steel 1.4301
Ground disks
1.4435 (316L), Alloy C22
Measurement, reference and empty pipe detection electrodes available as standard with:
• 1.4435 (304L)
• Alloy C22
Proline Promag L 400 HART
Endress+Hauser

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Proline Promag L 400 and is the answer not in the manual?

Table of Contents