Service
Filter replacement
The fi ne fi lter should be replaced at least once a
year. HEPA fi lters should be replaced after every
300 hours of operation. Wear a dust mask when
replacing the fi lter. Only use an original fi lter.
Release and lift off the lid. To prevent the escape
of dust, place a plastic sack over the cyclone, and
remove the fi lter cartridge. Clean the fi lter plate.
Then fi t the new fi lter.
- CAUTION! Do not reuse the main fi lter once it
has been removed from the machine.
The HEPA fi lter is removed by withdrawing the car-
tridge after opening the lid. Insert the new HEPA
fi lter into the holder on the motor head, then insert
the new fi lter cartridge into the machine and close
the lid.
Caution
The manufacturer or a trained person must carry
out an inspection at least annually, e.g. damage to
the fi lter, air-tightness of the dust-extraction ma-
chine and the function of the control unit.
The turbopump has a very long service life and
requires no maintenance. After approximately
10,000 hours of operation, the radial seal between
the motor and the pump should be lubricated with
bearing grease. The bearings and seals of the
electric motor must be inspected at the same time.
These must be lubricated and replaced, if
necessary. If any other wear is observed, the parts
concerned must be replaced.
Safety-relevant accessories included
Description
Suction hose 38, ESD-certifi ed
Suction hose 50, ESD-certifi ed
Coupling socket 50/50 ESD-certifi ed
Connecting sleeve 38/38 turnable
ESD-certifi ed
Intermediate sleeve 50/38,
ESD-certifi ed
HEPA fi lter DC 3800 H Turbo EX
Fine fi lter, antistatic
Sealing plug, inlet
Plastic sack, conductive
Floor nozzle 450 A-38 ESD-certifi ed
2017-06-29
Part No.
We can supply all safety-relevant spare parts
and wearing parts.
2027E
2028E
Dustcontrol UK Ltd.
2107E
Old Barn, Home Farm
Business Park
2114E
Church Way, Whittlebury,
Northants NN12 8XS
2120E
Tel: 01327 858001, sales@dustcontrol.co.uk,
42024H
www.dustcontrol.co.uk
4202501H
See the Dustcontrol catalogue for other ac-
42250H
cessories.
42384H
7236E
DC 3800 H Turbo EX can be ordererd with
antistatic accessories to fulfi l the requirements
of the ATEX Zone 22 directive 2014/34 ATEX
137
.
DC 3800 H Turbo EX - 18
Part No 94264
Need help?