EOS EmoStyle Di Installation And Operation Manual

Sauna control unit
Hide thumbs Also See for EmoStyle Di:

Advertisement

I N N O V A T I V E S A U N A T E C H N O L O G Y
EmoStyle Di
EmoStyle Hi
sauna control unit
Installation and operation manual
EN
Made in Germany
Druck Nr. 29344816 en / 41.17
technical changes reserved

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EmoStyle Di and is the answer not in the manual?

Questions and answers

Summary of Contents for EOS EmoStyle Di

  • Page 1 I N N O V A T I V E S A U N A T E C H N O L O G Y EmoStyle Di EmoStyle Hi sauna control unit Installation and operation manual Made in Germany Druck Nr. 29344816 en / 41.17...
  • Page 2: Table Of Contents

    ENGLISH Contents Delivery scope ................................. 4 Accessories ................................4 Technical specifications ............................5 General notes for sauna bathing ........................6 General safety notes ............................... 7 Mechanical installation ............................9 Relay box ...............................9-10 Display panel ..............................11 Temperature sensor ............................14 Electrical connections ............................16 Sauna heater connection ..........................16 Sauna lamp connection ..........................17 Connection of power extension units (LSG) ..................17...
  • Page 4: Accessories

    Scope of delivery (changes and modifications are reserved) Main electronic unit (with two-part front cover) Control panel with colour display 2.1 - voltage regulator Housing base for flush-mounted installation of the control panel, with mounting brackets De-installation tool (for control panel) Temperature sensor: a) housing, b) sensor board, c) overheat protection fuse, d) 2 mounting screws 4 x 40 mm, e) connection cable 5 m with RJ10 plug, f ) 2-core white cable for overheat- ing protection fuse 5 m...
  • Page 5 Technical data Voltage (power supply): 400 V 3 N AC 50 Hz Switching capacity: max. 9 kW resistive load, extendable with a power extension unit (LSG) Heating time limit: 6 h / 12 h / unlimited Housing: plastic, shatter-resistant Display: TFT colour display 55 x 74 mm (3,5“...
  • Page 6 General information Dear customer You have purchased a high-quality technical Please check whether the unit has arrived in per- device with which you will have years of sauna fect condition. Any transport damages should be fun. This sauna control unit was designed and immediately reported to the freight forwarder inspected according to the current European delivering the goods or you should contact the...
  • Page 7 General safety precautions ature setting. The temperature can be held within operating parameters and a mini- This device can be used by children aged • mal temperature gradient inside the bench 8 upwards and by persons with physical, area of the sauna cabin can be achieved sensory, or mental disabilities, or who only if unit is assembled correctly.
  • Page 8 When designing the sauna cabin ensure that the external exposed glass surfaces only reach a maximum tempera- ture of 76°C. If necessary, protective fea- tures need to be fitted. ! Attention! Dear customer, according to the valid regulations, the electrical connection of the sauna heater and the control box has to be carried out through the specialist of an authorized electric shop...
  • Page 9: Relay Box

    Installation of the main electronic unit The main electronic unit (relay box) may be installed only outside sauna cabin. The recommended places of installation are the outer sauna wall or a plant room (technical room). The installation on the sauna roof is also possible. If empty ducts for connection cable are already available, then they usually predetermine the installation position.
  • Page 10 Hang the housing on the central upper screw. Make sure that this screw stands out ap- prox. 3 mm from the wall surface. If the connection cables shall be connected from the rear, knock out the corresponding openings in the housing and insert the supplied cable glands (rubber cable holders) into these openings.
  • Page 11: Relay Box

    Control panel Cable connection Installation place Draw the connection cable from the relay box to the control panel. The control panel may be mounted inside sau- The connection cable may be laid only be- na cabin on the sauna wall. If ductwork is al- tween the outer sauna wall and insulation layer ready provided for electrical installations then to prevent overheating (Fig.
  • Page 12: Display Panel

    Notice for display panel position Display panel installation inside sauna rooms in zone 2 only! Area 3 Never mount directly above or in the vicinity of the Area 1 sauna stove (zone 1), or within the direct radiation range of short-wave infrared emitters. Area 2 ATTENTION! 0,7 m...
  • Page 13 Installation of the display panel The separate wire-con- Bauteil nected component of the control panel has to be placed within approx. 3 m, e.g. on the sauna wall. hier Werkzeug anlegen Fig. 8 Fig. 9 Place the display panel in front of the bottom housing, pay attention to the correct orientation (display up, buttom down).
  • Page 14 Connection of sensor cables Do not lay sensor and power supply lines together, or lead them through the same duct. This can lead to interferences in the electronics, such as “fluttering” in the relays. Connect the cable shield- ing (if present) to ground in the control unit. Please observe that the following dimensions relate to the values stipulated during the unit in- spection acc.
  • Page 15: Temperature Sensor

    Lead the sensor cable (red) and the limiter cable (white) through the drilled hole and connect both cables to the main relay box as advised on pages 18-19. Connect the sensor cable to the sensor board according to fig. Make sure the connections are correct.
  • Page 16: Electrical Connections

    Electrical connection Sauna heater connection The electrical connections may only be car- ried out by a certified electrician in compli- ance with the guidelines of the local power Install the sauna heater and the vaporizer in supply company and applicable legal regu- front of the air intake according to the manu- lations (e.g.
  • Page 17: Sauna Lamp Connection

    Sauna lamp connection Heating time limitation The maximal heating time may be limited with The sauna lamp must have the protection the jumper #5 on the main board of the relay class of at least IPx4 and should be resistant to box.
  • Page 18 Installation diagram Emotec D / Emostyle D/Di Feuchtefühler Steckeranschluß Fühler humidity sensor Sensor plug connector Bankfühler/2nd Sensor Ofenfühler/Sensor reserviert Leistungsteil Sensorbus Main unit (relay box) Relais box Saunabus light S1 S1 N L1 L2 L3 N W V U N L N L N Leuchte/light Lüfter/fan Bedienteil...
  • Page 19 Installation diagram Emotec H / Emostyle H/Hi Feuchtefühler Steckeranschluß Fühler humidity sensor Sensor plug connector Bankfühler/2nd Sensor Ofenfühler/Sensor reserviert Leistungsteil Sensorbus Main unit (relay box) Relais box Saunabus light S1 S1 N L1 L2 L3 N W V U N L N L N Leuchte/light Lüfter/fan Bedienteil...
  • Page 20: Temperature Sensor Connection

    Temperature sensor ! ATTENTION! Feuchtefühler Humidity sensor Bankfühler Connecting a sensor to the sauna bus 2nd sensor Ofenfühler reserviert connector (RJ12) may damage the sensor Main sensor reserved and the main board of the control unit! Sensorbus RJ 10 The sensors are connected via RJ10 modular plugs to one of the corresponding sensor bus RJ10 jacks on the main board of the relay box Saunabus...
  • Page 21 Humidity Feuchtefühler Humidity sensor Bankfühler sensor installation 2nd sensor Ofenfühler reserviert Main sensor reserved Sensorbus RJ 10 1. The humidity sensor shall be mounted in the Connection over- middle of the wall opposite to the heater at view for tempera- Saunabus ture sensor, bench approx.
  • Page 22: Vaporizer Connection (Bi-O Type Heaters)

    Make sure to use the appropriate heat-resistant silicone cable with min. 1,5 mm² cross section for vaporizer connection. EOS control units will detect water shortage if there is zero potential at the Wm terminal of the control unit. Pay attention to the maximum switching pow- er of the control unit vaporizer output.
  • Page 23 Installation of the The sensor symbol will be displayed either on the start screen (Emotec, EmoStyle models) or optional 2nd sensor in the temperature query submenu (EmoTouch models). If the 2nd sensor is faulty the temperature will Place of installation: The 2nd sensor (bench be controlled via the main sensor over the sensor) shall be mounted on the ceiling over heater.
  • Page 24 Putting into service (initial setup) Setup after initial start or after a reset The EmoStyle control unit allows fast and intuitive configuration in several steps by commission- ing during the first start or after a system reset. Select language Sprache Select the required language with the buttons and confirm your slection by pressing briefly on the enter button...
  • Page 25: Operation

    The setup is now complete and the control unit will switch to the standy mode. 20:51 20:51 Display in standby mode by Display in standby mode by dry (Finnish) sauna operation humid (Bi-O) sauna operation (EmoStyle D/Di und H/Hi). (nur EmoStyle H/Hi). Cabin light switched on.
  • Page 26: Overview

    Operation Control panel - overview Sauna (heating) On / Off Thermometer sym- press for 3 sec to switch the heater on bol - stands for dry sauna mode if no Light cloud is shown. On / Off Cloud symbol - indicates selected Up / Down 09:12...
  • Page 27 Operation principle Use up/down buttons in order to select a certain function. Press “enter” shortly to open this func- tion. Use up/down buttons to change the value (changed value turns green from white). Press en- ter shortly to save (confirm) the setting and exit, the control panel will then return to the previous (upper) menu.
  • Page 28 Symbol description - extended settings „Extended settings“ sub-menu provides a range of additional functions, which normally need to be set only once or quite seldom. Select the symbol in the main menu and press the enter button shorly to open the sub-menu. Language Time Allows to set the language for the menu navi-...
  • Page 29 Graphic user interface (GUI) and the current climate conditions check Thanks to the modern graphic user interface you can quickly access all functions and make neces- sary settings, as well as make a simple instant query for the current sauna climate condition. The symbols on the start screen may be displayed in different colours, in order to indicate the cur- rent operation status - e.g.
  • Page 30 Operation and program settings Sauna on / off Press the button on the control panel for approx. 3 seconds to switch the sauna on. Count- down runs . The display will show the active heating state (see previous page). The cabin light will be also switched on.
  • Page 31 Please observe that with a humidity sensor the humidity rH [%] setting will depend on the pre-set temperature. For safe- ty reasons only the values to the left and under the curve may be selected. For instance at 60°C temperature your can set up to 40% rel.
  • Page 32 Timer Temperature Timer Timer (switch-on time pre-selection) The timer function allows you to have your sauna switched on automatical- ly with the desired climate condition at some time in the future. You have Auswahl two possible options: Select event Einzeltermin - single event (single time switching, not recurrent) 20:51 20:51...
  • Page 33 instance during peak-off times you may set the sauna to run at lower temperatures with reduced ener- gy consumption, so that it can then reach the full temperature faster at the main time of use. Now select the program (1 of 4) and press enter. Set the required start time (hours and minutes) - e.g.
  • Page 34 In this mode the display brightness will be reduced to the minimum and the display will show the current time (or EOS-Logo) floating across the screen. Touch the up/down or the on/off buttons shortly in order to return to the start screen.
  • Page 35 open and display „0000“. You can now replace the zeros with your personal 4-digit pin code. Use up/down to select a number, press enter to confirm it and to jump to the next digit. After the 4 digit confirmation the display will return to the start screen and the unit is now locked. Notice: make sure to remember the pin-code! For safety reasons it is still possible to switch off the heater (interrupt active heating) and to switch the light while the unit is locked.
  • Page 36 Operation data Here you can check the important information concerning your control unit (sauna) operation. Firmware - allows to check the currently installed firmware version. Press enter to switch between two possible parameters. „Panel Vx.xx“ - shows the firmware in control panel, „Mod-LS Vx.xx“...
  • Page 37 Service- and Setup The control unit provides an extensive scope of functions for setup and fine-tuning of the sauna equipment in order to optimize sauna operation. This setup menu is protected with a PIN code and should not be accessible to the end users. Hint: a short version of the operation manual without setup and installation is included with every controller.
  • Page 38 Symbol description Service intervals Basic-Setup Intervals for servicing & maintenance in hours. Setting of the sauna use type and of the heater type. Reset Reset to the factory default settings, all individual Fan speed settings. settings will be deleted. Refilling time Contact details Grace time to refill the vaporizer (only EmoStyle H) Displays stored contacts.
  • Page 39 cally switch on with the heater (synchronous operation). In „sauna dry“ program the fan will always operate at the highest speed. Refilling time (only Bi-O heaters) Here you can set the grace time which the end user has to refill the vaporizer after the water short- age alarm.
  • Page 40 Contact details Here you can check the stored contact details. By default the contacts of the control unit manu- facturer will be shown. If an optional micro-SD card with personalized firmware is inserted, the individual contact details will be shown. Potential-free contact Allows to enable (p) or disable ( ) the potential-free contact switching function.
  • Page 41 • Check cable connections and restart the control unit; if the fault persists, contact the dealer or EOS service. If any other unidentified error messages appear, please contact EOS service. Make sure to supply the serial number, fault details and other relevant information.
  • Page 42 The device „Switch-off“ switch The control unit is equipped with a “Switch-off” rocker switch. You will find this switch on the top side of the housing by Econ series control units and on the left side of the main relay box by control units of Emotec, EmoStyle and EmoTouch series.
  • Page 43: Service Address

    Service Address: EOS Saunatechnik GmbH Schneiderstriesch 1 35759 Driedorf, Germany Tel: +49 (0)2775 82-514 Fax: +49 (0)2775 82-431 servicecenter@eos-sauna.de www.eos-sauna.de Equipment commissioning date: Please keep this address in a safe place togeth- er with the installation guide. Stamp and signature of the authorized elec-...
  • Page 44: Warranty

    General Terms and Conditions of Service shipments via parcel post. The manufacturer shall accept no liability for damage incurred as a result of improper I. Scope packaging in an individual shipment. Unless otherwise agreed in writing in a specific case, VI.

This manual is also suitable for:

Emostyle hi

Table of Contents