Adjustment Method; Dummy Load - JVC KS-F525 Service Manual

Nexsens cb-650
Hide thumbs Also See for KS-F525:
Table of Contents

Advertisement

KS-F525
QQ
3 7 63 1515 0

Adjustment method

Test Instruments reqired for adjustment
1.Digital osclloscope(100MHz)
2.Frequency Counter meter
3.Electric voltmeter
4.Wow & flutter meter
5.Test Tapes
VT724
VT739
For playback frequency measurement
VT712
For wow flutter & tape speed measurement
VT703
For head azimuth measurement
6.Torque gauge
Measuring conditions(Amplifier section)
Power supply voltage
Load impedance
Line out
TE
Standard volume position
L 13942296513
Balance and Bass,Treble volume .Fader
:Center(Indication"0")
Loudness,Dolby NR,Sound,Cruise:Off
Volume position is about 2V at speaker output with
following conditions.Playback the test tape VT721.
AM mode 999kHz/62dB,INT/400Hz,30%
modulation signal on receiving.
FM mono mode 97.9MHz/66dB,INT/400Hz,22.5kHz
deviation pilot off mono.
FM stereo mode 1kHz,67.5kHz dev. pilot7.5kHz dev.
Output level 0dB(1 V,50 /open terminal).
www
1-12
http://www.xiaoyu163.com
for DOLBY level measurement
Cassette type for CTG-N
(mechanism adjustment)
DC14.4V(10.5~16V)
4 (2Speakers connection)
20k
x
ao
y
.
i
http://www.xiaoyu163.com
8
Frequency Range
FM1/FM2 : 87.5 MHz to 108.0 MHz
FM3 :
65 MHz to 74 Hz
AM :
(MW) 522 kHz to 1620 kHz
(LW) 144 kHz to 279 kHz

DUMMY LOAD

Exclusive dummy load should be used for AM
and FM dummy load,there is a loss of 6dB
between SSG output and antenna input. The
loss of 6dB need not be considered since
direct reading of figures are applied in this
working standard.
Q Q
3
6 7
1 3
Arrangement of Adjusting
Cassette Mechanism Section
Capstan motor
Cassette mechanism
(Surface)
Azimuth screw
(Forward side)
u163
Azimuth screw
(Reverse side)
.
2 9
9 4
2 8
1 5
0 5
8
2 9
9 4
Tape speed adjust
Playback head
m
co
9 9
2 8
9 9

Advertisement

Table of Contents
loading

Table of Contents