Before fitting the cover, make sure that the appropriate cutouts have been
removed to suit the supply entering the product.
Thoroughly flush the mains-fed cold water supply pipe. The supply must
be clean and free from debris BEFORE connecting the appliance.
To flush the pipework, turn on the water supply and drain a minimum of 10 litres
(2 gallons) of water into a bucket or catchment area. Turn off the water supply.
An installation template is supplied to help you install the Mira Alero.
Put the installation template on the wall and mark through the positions of the
fixing holes. Ensure the position of these holes do not come in line with any
buried cables or pipework. Make sure that sufficient electrical supply cable is
available for connection to the terminal block.
Drill and plug the top two fixing holes. Secure the appliance to the wall with
appropriate screws. Drill the bottom fixing hole with the product in place.
Alternative fixings (not supplied) may be necessary for some wall structures.
Avoid drilling into any supply cable/pipe.
Install the mains-fed cold water
supply pipe. Do not overtighten.
( S e e P l u m b i n g I n s t a l l a t i o n
Requirements).
Feed cable into case. Fit Earth sleeve
(not supplied) and then strip insulation.
Do not twist cable cores.
Important! Make sure that the inlet earth
wire is routed as shown. Failure to do so may
cause product malfunction.