Download Print this page

Viking 40TB-IP Product Manual page 18

Ip ceiling speaker for sip endpoint paging or multicast paging/background music, and making standard or emergency sip calls
Hide thumbs Also See for 40TB-IP:

Advertisement

A. Making an Outbound Call
When the "CALL" button is pressed, the 40TB-IP speaker phone dials a pre-programmed telephone number. The Call
Connected LED momentarily flashes during dialing. In the event the line is busy or there is a ring-no-answer, the unit
can be programmed to call additional phone numbers.
The phone then cycles through up to 5 pre-programmed numbers until the call is answered. When the call is answered,
the phones are factory programmed to automatically light the "Call" LED to show that handsfree communication to
personnel is established. Once the "Call" LED is on, relay activation commands can be entered or the # key can be
used to force the phone to hang-up.
After communication is established, enter the 1 or 2 digit relay activation command (factory set to "QQ") to momentarily
activate the speaker phone (door strike) relay. If you require the relay to remain on continuously (ie: a truck delivery),
enter Touch Tones "Q1" to continuously activate that relay. A double beep will indicate the (door strike) relay is latched
on. When the visitor calls in again (ie: they are finished unloading the truck), enter Touch Tones "Q0" to deactivate the
relay. A single beep will indicate the (door strike) relay is latched off.
B. Remote Access Operation Commands
The following commands can be entered after answering an inbound call from the speaker phone. The commands can
also be entered on an outbound call to the speaker phone. After the speaker phone auto answers the call, two beeps
will be heard. If the access code has been disabled, you can now enter the Remote Access Operation Commands below.
If an Access code has been programmed, enter the Access code digits. With the correct code entered, two beeps will
be heard and you can now enter the Remote Access Operation Commands below.
Feature
Activate
Relay
Un-Latch
Relay
Latch
Relay
Disconnect
Send ID and
Play Message
* Note: Latching commands must be enabled (Q6) in programming.
If the unit cannot register with the programmed SIP server, the "Call" LED will blink on and off every two seconds, and three
error beeps will be heard every 30 seconds until communication is restored. This alerts a potential user of a problem with
the device that will prevent an emergency phone call from being made.
You may silence the error beeps, per instance, by pressing and holding the CALL button for 5 seconds or by clicking the
"Mute Alarm Until Next Failure" button in the Viking VoIP Programming Software (see section on page ?). The error beeps
automatically re-enable once the unit is registered, to alert of any new problems that arise.
Tone Tone
Description
Command
QQ or
Momentarily activate relay (1 or 2 digits, factory set to QQ).
___ ___
Q0
Un-latch* (deactivate) the relay.
Q1
Latch* (continuously activate) the relay.
#
Disconnects or forces the emergency phone to hang up.
Q
Send I.D. number (if programmed) and plays the announcement.
Troubleshooting
Operation
18