23. LED Mode
The "Call" LED on the 40TB-IP can be programmed to one of four different modes: OFF, ON, Phone or paging or Outbound phone.
OFF Mode: Useful for silent monitoring applications. In this mode the LED will not light during normal operation. It will only light
(blink) if it cannot register with the programmed SIP server or while manually resetting all network parameters to factory default.
On Mode: The LED will remain ON in the idle state, turn off while button is pressed, blink during dialing, light steady when the call
is answered, then turn OFF momentarily when the call is completed.
Phone or Paging Mode: The LED will remain OFF in the idle state, blink during dialing, light steady when the call is connected, then
turn OFF when the call is completed. The LED will also light steady during paging.
Outbound Phone Only: On outbound calls, the LED will remain OFF in the idle state, blink during dialing, light steady when the call
is connected, then turn OFF when the call is completed. On in-bound calls, the LED will remain off. This is useful for silent monitoring
on inbound calls.
24. Enable/Disable Alternate Switch Action
When set to "Enabled" (factory default) the hard wired CALL button or center button on BTR-3 alternately connects and disconnects
calls. When set to "Disabled" the CALL button connects calls only. Pressing the button again after the call has been initiated will not
terminate the call.
25. Phone Name
Up to a 31 character phone name can be assigned to the 40TB-IP being programmed. Often times the building name
and entrance location near the unit are used for the name.
26. Mute Current / Next Alarm
A network failure alarm will be indicated by providing 3 beeps every 30 seconds. A network failure indicates the unit is
not registered to the SIP server or there is a communication failure with the gateway. The three beeps can be muted by
clicking on "Mute Current / Next Alarm".
27. IP Firmware
If new 40TB-IP firmware is available, after opening the programming software a pop window will come up asking you if
you would like to update firmware. An alternative method of updating can be done by clicking the IP firmware "Update"
button. You can then browse to the folder that contains the PIP file for updating the unit's IP firmware. This method is
typically only used when Viking Technical Support has sent you updated IP firmware
28. Phone Firmware
If new 40TB-IP firmware is available, after opening the programming software a pop up window will ask if you would
like to update firmware. Another way to update is accomplished by clicking the phone firmware "Update" button. You
can then browse to the folder that contains the HEX file for updating the unit's firmware. This method is typically only
used when Viking Technical Support has sent you updated firmware.
29. Import/Export
The Import/Export feature is useful for backing up all the 40TB-IP's programming or for importing programming when
installing multiple units with a majority of the same programming.
30. Default Phone Settings
Clicking on the "Default Phone Settings" button in programming will reset all of the Programming Features back to their
factory default settings. Note: This command will not change or reset your IP settings.
31. Diagnostics
The Diagnostics section in the Viking IP Programming can be used to test the functionality of the mic, speaker and
relay.