3.4 Self-diagnostic mode

This section describes LEVEL 0 and LEVEL 1.

3.4.1 Operator Panel

The following operational description on the self-diagnostic is premised on the following
operator panel layout:
Example : MB472dnw
45762101TH Rev.1
(1) Menu option switching
Self-diagnostic
Only while displayed as shown in a shaded area (
mode layout (entire)
the level of the self-diagnostic mode can be switched. [2] or [8] is
used to switch to the option in a non-shaded area ( XXXXX ).
Normal operation mode
LEVEL0- engine status
display
[6]
Engine status display
Respective voltages display
during print
Toner sensor monitor
Toner pulse count monitor
[6]
Toner TAG noise test monitor
Motor controls evaluation
function
Error detail
3. MAINTENANCE MENUS
XXXXX
),
LEVEL1-ENGINE DIAG MODE XX.XX
SWITCH SCAN
MOTOR & CLUTCH TEST
TEST PRINT
CONSUMABLE STATUS
PRINTER STATUS
FACTORY MODE SET
SENSOR SETTING
LED HEAD DATA
NVRAM PARAMETER