Kenwood TK-80 Service Manual page 51

Hf ssb radiotelephone
Hide thumbs Also See for TK-80:
Table of Contents

Advertisement

TK-80
Item
3. IF AMP
1) M CH: 08
adjustment
[DATA]: 1 push
[MODE]: 1 push
Mode: USB
SSG f.: 14.151MHz
SSG OUT: –113~–119dBm
4. MIX BAL
1) M CH: 09
adjustment
AIP: OFF
SSG OUT: OFF
5. IF GAIN
1) M CH: 10
adjustment
SSG f.: 14.150MHz
SSG OUT: –103dBm (1.58µV)
2) SSG OUT: –113dBm (0.501µV)
3) SSG OUT: –103dBm (1.58µV)
6. S-meter
1) Power ON while holding the
adjustment
[SCAN] and [DATA] keys.
S1
(Service adjustment mode)
Menu No.: 29
SSG f.: 14.101MHz
SSG OUT: –107dBm (1µV)
S9
2) Menu No.: 30
SSG OUT: –81dBm (19.9µV)
Full scale
3) Menu No.: 31
SSG OUT: –41dBm (1.99mV)
7. SQL
1) Menu No.: 32
threshold
SSG OUT: OFF
adjustment
SQL VR: Center
8. SQL VR
1) Menu No.: 33
adjustment
SSG OUT: OFF
SQL VR: Center
9. CLARI VR
1) Menu No.: 34
adjustment
SSG OUT: OFF
CRARI VR: Center
10. Beep sound 1) Menu No.: 37
adjustment
11. Sidetone
1) Menu No.: 38
adjustment
12. ROM data
1) Turn the [DIAL] to select Menu No. 39.
writing
13. NB check
1) Press [MENU] key one time,
set to the menu number "02" generator
by pressing [DATA] or [MODE] D.V.M
key, and NB is ON for turning
the [DIAL].
Adjust the noise generator to
S1, S9 level, then check.
After the check, press the
[MENU] key one time.
50
Downloaded from
www.Manualslib.com
Measurement
Condition
Test-
equipment
SSG
AF V.M
Oscilloscope
DM. SP
(0.501~0.25µV)
Noise
manuals search engine
ADJUSTMENT
Adjustment
Terminal
Unit
Unit
Parts
Rear
ANT
TX-RX L44
panel
L48
EXT.SP
L49
L51
L75
L76
VR1
Front
AF VOL AF output: 0.63V
panel
TX-RX VR4
Front
[MODE] 1 push
panel
or
[DATA]
TX-RX VR9
VR10
Display (READY) → Press [MODE] or [DATA] → Write → Finish (GOOD)
Specifications/Remarks
Method
Repeat adjustment
2 to 3 times.
AF output: MAX
Noise minimum
AF output: 0.4V
± 0.05V
Check
0.63V± 0.05V
1 push
1 push
1 push
0.25V
± 6dB
0.2V
± 6dB
Check
Noise decreases

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents