Ref. No.
Use / Function
D45
LED
D47
Reverse flow
prevention
D48
PIN diode
D49
Reverse flow
prevention
D50,51
Switching
D52,53
Detection
D54
Detection
D55
Detection
D56
Switching
D59
Detection
D60,61,63
Reverse flow
prevention
D64
Rectification
D65
Zener diode
D66
Surge absorption Protect for transistor of linear
D67
LED
D68
Zener diode
D69,70
Reverse flow
prevention
Downloaded from
www.Manualslib.com
COMPONENTS DESCRIPTION
Operation / Condition
Voltage limiter
Diode of 10.695MHz level variability
ON in transmit
SSB, CW envelope detection
AM envelope detection
AGC squelch detection
ON in transmit
Detection of MIC amplifier output
DC/DC converter
For constant voltage
amplifier control
Voltage limiting
3.6V voltage shift
manuals search engine
Ref. No.
Use / Function
D71
Zener diode
12V voltage shift
D72,73
Reverse flow
prevention
D75
Zener diode
Reduce the output power when
power supply voltage drop
D76,79
Reverse flow
prevention
D80
Zener diode
Reduce the output power when
power supply voltage drop
D81~87
Reverse flow
prevention
D88
Zener diode
Over voltage protection
D500,501
Switching
DDS register selection
D502
Vari-cap
VCO1
D503
Switching
VCO1 output
D504
Vari-cap
VCO2
D505
Switching
VCO2 output
D506
Vari-cap
VCO3
D507
Switching
VCO3 output
D800
Detection
Noise detection
D900~902
Reverse flow
prevention
TK-80