Summary of Contents for Allen-Bradley 6153

  • Page 1 Industrial Computers (Bulletin 6153, 6154) Product Data & Installation Instructions...
  • Page 2 In no event will the Allen-Bradley Company be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment.
  • Page 3 Note: Check your shipment against the packing list in the shipping carton. Some of these items may not be needed for your option. Bulletin 6153 and 6154 Industrial Computers are shipped with the following items: computer with integrated 20” Color CRT 1.82 m (6 ft.) AC Power Cord (optional)
  • Page 4 Bulletin 6153 and 6154 Industrial Computers with Integrated CRT Figure 1 Physical Dimensions Dimensions of Bulletin 6153 Industrial Computer, 4 slot. Publication 6153-2.0...
  • Page 5 Bulletin 6153 and 6154 Industrial Computers with Integrated CRT Figure 2 Dimensions of Bulletin 6153 Industrial Computer, 8/12 slot. Publication 6153-2.0...
  • Page 6 Bulletin 6153 and 6154 Industrial Computers with Integrated CRT Figure 3 Dimensions of Bulletin 6154 Industrial Computer, 4 slot. Publication 6153-2.0...
  • Page 7 Bulletin 6153 and 6154 Industrial Computers with Integrated CRT Figure 4 Dimensions of Bulletin 6154 Industrial Computer, 8/12 slot. Publication 6153-2.0...
  • Page 8 Remember to allow extra space for air circulation. Bulletin 6153 with 4 slots, Figure 1 on Page 4. Bulletin 6153 with 8/12 slots, Figure 2 on Page 5. 3. Refer to the panel cutout drawing for your unit for dimensions of the panel cutout and location of mounting holes.
  • Page 9 Bulletin 6153 and 6154 Industrial Computers with Integrated CRT 5. Remove the external bezel. 6. Insert the computer in the panel cutout from the front of the panel. 7. Place the washers (one of each) on the bolts provided and install through the front panel.
  • Page 10 Bulletin 6153 and 6154 Industrial Computers with Integrated CRT Figure 5 Panel Cutout for Bulletin 6153 4-slot Industrial Computer Publication 6153-2.0...
  • Page 11 Bulletin 6153 and 6154 Industrial Computers with Integrated CRT Figure 6 Panel Cutout for Bulletin 6153 8/12-slot Industrial Computer Publication 6153-2.0...
  • Page 12 Bulletin 6153 and 6154 Industrial Computers with Integrated CRT Rack Mounting, Bulletin 6154 The 6154 Industrial Computer can be installed in a rack cabinet that conforms to EIA standards for equipment with 19” wide panels. The cabinet must be tall enough to accommodate the computer’s height and deep enough to accommodate the unit’s depth, while providing...
  • Page 13 Bulletin 6153 and 6154 Industrial Computers with Integrated CRT Connecting AC Power The computer requires a single phase power supply providing 90-132V AC or 180-264V AC at 47 to 63 Hz. Power must be available at the three-pin AC input receptacle situated in the rear of the unit.
  • Page 14 Controls & Indicators The following is a summary of the controls and indicators on the Bulletin 6153 and 6154 Industrial Computer. Refer to figures 7 through 10 for help in locating specific controls or indicators. Figure 7 Front Controls – 4-Slot Units...
  • Page 15: Power Indicator

    180600 Bulletin 6153 8/12 Slot CONTRAST DEGAUSS RESET POWER Bulletin 6154 8/12-Slot 180597 Power Indicator The presence of AC power at the Bulletin 6153 or 6154 Industrial Computer is indicated by a green LED in the front panel. Publication 6153-2.0...
  • Page 16 Bulletin 6153 and 6154 Industrial Computers with Integrated CRT Contrast and Brightness Controls The Bulletin 6153 and 6154 Industrial Computers are equipped with adjustable contrast and brightness controls. The 4-slot units have duplicate controls on the front and the back of the unit. The 8/12-slot units have a contrast control on the front, and both contrast and brightness controls on the back.
  • Page 17 Bulletin 6153 and 6154 Industrial Computers with Integrated CRT Degauss The monitor is equipped with an automatic degaussing system to remove residual magnetism from the CRT’s shadow mask at power-up. Degaussing helps keep the screen free of any color impurities which might otherwise result from magnetism picked up by the shadow mask from the earth’s magnetic field when the...
  • Page 18 Bulletin 6153 and 6154 Industrial Computers with Integrated CRT Figure 10 Rear Panel Controls – 8/12-Slot Units Factory Adjustments Vertical Position Horizontal Size Horizontal Position – + – + – – AUX 2 Degauss Raster Rotation Brightness Contrast Vertical Size Note: The internal degauss will not prevent color impurities caused by local magnetic fields.
  • Page 19 Bulletin 6153 and 6154 Industrial Computers with Integrated CRT Installing Cables You will need to connect a number of cables at the rear of the unit before your Industrial Computer will function. This section describes the cable connections you will need to make. While installing cables, be sure to keep the following points in mind.
  • Page 20 Bulletin 6153 and 6154 Industrial Computers with Integrated CRT Figure 12 Rear Panel Cable Connections – 8/12-Slot Units Video Cable – + – + – – Touchscreen Serial Cable AUX 2 (Optional) Front Panel Keyboard Connector Monitor Power Cord Publication 6153-2.0...
  • Page 21 Bulletin 6153 and 6154 Industrial Computers with Integrated CRT Video Cables The HD15 cable is equipped with a conventional HD15 connector at each end. Figure 13 Standard VGA Cable View looking into the Pin End of the Male connector HD15...
  • Page 22 Bulletin 6153 and 6154 Industrial Computers with Integrated CRT Touchscreen, mouse and other input device setup To set up the front panel keyboard To enable the front panel keyboard connector, use a 5-pin DIN keyboard cable (4- or 12-slot units) or a PS2 keyboard cable (8-slot units) at the rear of the unit.
  • Page 23 Bulletin 6153 and 6154 Industrial Computers with Integrated CRT To open the computer chassis You may have to open the computer chassis to install a card or for some other reason. 1. Disconnect and remove cables from the computer chassis.
  • Page 24: Troubleshooting

    Note: The solvent should be applied only to the cloth, and not directly to the surface to be cleaned. Troubleshooting The following table can help you identify the potential cause of problems you may encounter while using the 6153 or 6154 Industrial Computer. Symptom Possible Cause...
  • Page 25: Specifications

    Bulletin 6153 and 6154 Industrial Computers with Integrated CRT Specifications Processor/Memory 486DX4/100 MHz, Pentium/100 MHz, Processor/Speed (MHz) Pentium/166 MHz Memory Options 4M (for 486DX4/100 only), 8M, 16M, 32M, 64M System 16-bit ISA, 8 slots (active motherboard) System Bus Architecture 16-bit ISA, 4 or 12 slots (passive backplane)
  • Page 26 Bulletin 6153 and 6154 Industrial Computers with Integrated CRT Environmental (specifications assume standard configuration, excluding diskette drive) Temperature Operating +5 C to +45 C Storage -30 C to 60 C Relative Humidity 8% to 80% non-condensing Altitude Operating 0 to 10,000 ft. (3,000 m) Non-Operating 0 to 40,000 ft.
  • Page 27 Bulletin 6153 and 6154 Industrial Computers with Integrated CRT Notes Publication 6153-2.0...
  • Page 28 Rico Qatar Romania Russia–CIS Saudi Arabia Singapore Slovakia Slovenia South Africa, Republic Spain Sweden Switzerland Taiwan Thailand Turkey United Arab Emirates United Kingdom United States Uruguay Venezuela Yugoslavia Allen-Bradley Headquarters, 1201 South Second Street, Milwaukee, WI 53204 USA, Tel: (1) 414 382-2000 Fax: (1) 414 382-4444 Publication 6153-2.0 – February 1997 40061-390-01(A) Copyright 1997 Allen-Bradley Company, Inc.