STL360 Kit Assembly and Wiring
STL360H
STL360 floodlight kits come pre-wired and assemble on the RAB CU4 EZ
plate, allowing for mounting on round, rectangular or octagonal surface or
recessed boxes.
Mounting
Bar Screws
Universal
Mounting
Bar
Hook
Gasket &
Surface Plate
Wiring
Red pigtail is only used to switch
remote or additional fixtures.
STEALTH-IN-1114
STL360HBW
CU4 EZ Plate
Gasket
Insert
close-up
plug in
unused
hole
Center
Screw
Finishing
Cap
O-Ring
Gasket
Red
(pigtail)
Black
Red
Black
Power In
White
White
Ground
Ground
7
1.
Attach the Universal Mounting bar with the screws provided to the junc-
tion box. If you are attaching your STL360 kit to a surface mount weath-
erproof box, you must use with the metal mouting plate with gasket.
2.
Easy Wiring Tip:
Use the "S" shaped Hands
Free Hanging Hook to hold
the CU4 EZ Plate during wiring.
3.
Bring power leads and sensor
kit leads through holes in
gasket and plate into
junction box.
4.
Strip 1/2" of insulation from
all leads.
5.
Attach ground wire(s) to junction box grounding screw.
Connect as shown in wiring diagram on page 7.
6.
Twist on wire nuts. Secure with electrical tape.
7.
Align CU4 EZ Plate and metal surface plate with gasket (for use with
surface mounted junction boxes) to ensure proper seal. Tighten CU4 EZ
Plate center screw (make sure O-Ring gasket is on the screw) to attach
CU4 EZ Plate to the box.
8.
Insert plastic Finishing Cap in the center of the CU4 EZ Plate for a weath-
erproof seal.
9.
Use silicone sealant around plate and all opening to ensure a weather
proof seal. Seal all unsued conduit entries on surface junction box.
10. Screw in light bulbs. Turn on power. Conduct walk test to adjust
sensor response (see page 15).
Hood rests