OHAUS Ranger 7000 Instruction Manual

OHAUS Ranger 7000 Instruction Manual

Hide thumbs Also See for Ranger 7000:

Advertisement

®
Ranger
7000 Scales
Instruction Manual
1.800.561.8187
information@itm.com
www.
.com

Advertisement

Table of Contents
loading

Summary of Contents for OHAUS Ranger 7000

  • Page 1 ® Ranger 7000 Scales Instruction Manual 1.800.561.8187 information@itm.com www. .com...
  • Page 2 1.800.561.8187 information@itm.com www. .com...
  • Page 3 ® RANGER 7000 SCALES EN-1 TABLE OF CONTENTS 1. INTRODUCTION ........................4 Description ..............................4 Features ............................... 4 Definition of Signal Warnings and Symbols ....................4 Safety Precautions ............................4 2. INSTALLATION ........................5 Unpacking ..............................5 Installing Components ..........................6 2.2.1 Terminal Setup ............................. 6 2.2.2 Installing the Wind Ring, Weighing Platform ....................
  • Page 4 ® EN-2 RANGER 7000 SCALES 4.9.1 Application Setup ............................37 4.9.2 Differential Operation ..........................37 4.10 Sieve Weighing ............................38 4.10.1 Application Setup ............................. 38 4.10.2 Sieve Operation ............................39 4.11 Library ................................ 41 4.11.1 Creating a Library Record ........................41 4.11.2 Retrieving a Library Record ........................
  • Page 5 ® RANGER 7000 SCALES EN-3 5.9.7 Reference Balance ............................. 53 5.9.8 Reset ................................53 5.9.9 Stable Weight Only ............................. 53 5.9.10 SICS ................................. 53 5.9.11 Print Options ............................53 5.9.12 Auto Print ..............................53 5.9.13 Select Template ............................55 5.9.14 Edit Template ............................55 5.9.15 Edit String ..............................
  • Page 6: Description

    7000 SCALES INTRODUCTION Description The Ranger 7000 scale is a precision weighing instrument that will provide you with years of service if properly cared for. The Ohaus Ranger 7000 scales are available in capacities from 3000 grams to 60 kilograms. Features Modular Design: Ohaus Ranger 7000 scales are composed of two interconnected modules: a Terminal and a Base.
  • Page 7: Installation

    EN-5 INSTALLATION Unpacking Carefully remove your Ranger 7000 scale and each of its components from the package. The included components vary depending on the scale model (see table below). Save the packaging to ensure safe storage and transport. R71MHD15 R71MD15...
  • Page 8: Installing Components

    2.2.1 Terminal Setup When the Ranger 7000 is delivered, the Terminal is already attached (docked) to the Base. No additional setup is necessary. Refer to the illustrations and instructions below to identify and assemble your Ranger 7000 Scale. Note: The Terminal is identical for all Ranger 7000 Scale models.
  • Page 9: Connecting The Interface

    The Terminal communicates with the weighing base via the Terminal cable. This cable must be plugged into the Terminal for the Ranger 7000 to display properly. If desired, the Ranger 7000 scale may be operated either with the Terminal attached, or remotely (up to 1.5 meters away).
  • Page 10: Separating The Terminal From The Weighing Base

    ® EN-8 RANGER 7000 SCALES Separating the Terminal from the Weighing Base To detach, press both the Release buttons inward (both at the same time) and gently pull the Terminal towards you (outward) until the Terminal is detached. These Release buttons disengage the two hooks holding the Terminal to the Base.
  • Page 11: Operation

    ® RANGER 7000 SCALES EN-9 OPERATION Overview of Display, Home Screen CONTROLS Button Action Enter/Exit the library menu Switch between available application modes Send the measurement data to available communications ports according to current settings. Display information about Application Mode, Library, User and Menu Enter/Exit the User menu Switch the main weighing unit between the available units Short Press: Input ‘2’-‘9’...
  • Page 12: Principal Functions And Main Menu

    ® EN-10 RANGER 7000 SCALES Current Mode Capacity Assistance Information Stability Main Weight Field Gross (NET for net indicator) Capacity or Status Guides: Vary by application Reference Field Function Icons related to Smart buttons Principal Functions and Main Menu MENU & SCREEN NAVIGATION Press the Menu button to open the menu list.
  • Page 13: Overview Of Parts And Features

    ® RANGER 7000 SCALES EN-11 Overview of Parts and Features Weighing platform Power ON/OFF Button Base Level Indicator User adjustable leveling feet Terminal 1.800.561.8187 information@itm.com www. .com...
  • Page 14: Applications

    The scale can be configured to operate in various Application modes, see section 5.6 for information on how to activate/deactivate each application mode. Press to select an activated application. The current application will be shown in the upper left corner of the home screen (See section 3.1). The Ranger 7000 incorporates the following Applications Weighing Counting Check...
  • Page 15: Accumulation

    ® RANGER 7000 SCALES EN-13 The Configuration screen is now displayed. Select the list item and press the button corresponding to to change the setting as desired. To return to the Application home screen, press the button corresponding to The Weighing Configurations are defined below (defaults in Bold) Item Available Settings Comments...
  • Page 16: Input/Output (I/O) Setup

    ® EN-14 RANGER 7000 SCALES Clearing the Statistics / Accumulation results To clear the statistic / accumulation results, press the button A warning message appears. Press the button corresponding to the icon to confirm the deletion or press the button corresponding to the icon to abort the deletion and return to previous screen.
  • Page 17: Counting

    ® RANGER 7000 SCALES EN-15 The Weighing sub-menu is now displayed. Select the list item and press the button corresponding to icon to change the setting as desired. Counting Use this application to count samples of uniform weight. Counting Press the button until Counting is displayed in the upper left portion of the home screen.
  • Page 18 ® EN-16 RANGER 7000 SCALES Place 10 pieces of sample on the pan and press the button corresponding to the icon to perform sampling with default reference size. Note: The reference size can be changed in the Counting configuration. 2. Negative Sampling Place container with the samples on the pan and Tare the scale, a NET 0 will be displayed.
  • Page 19: Application Setup

    ® RANGER 7000 SCALES EN-17 4.2.2 Application Setup The Application can be customized for various user preferences. Press the button corresponding to the icon to enter Configuration The Configuration screen is now displayed. Select the list item and press the button corresponding to the icon to change the setting as desired.
  • Page 20: Accumulation

    ® EN-18 RANGER 7000 SCALES 4.2.4 Accumulation See section 4.1.2 for details about the Accumulation feature. 4.2.5 Input/Output (I/O) Setup The I/O’s can be customized for various user preferences. The I/O’s are defined below (defaults in Bold). Item Available Settings Discrete Input 1 Off, Zero, Tare, Clear Tare, Print, Unit, Accumulate Discrete Input 2...
  • Page 21: Check

    ® RANGER 7000 SCALES EN-19 4.3 Check Check is used to compare the weight or pieces of a sample against target limits. Press the button until Check is displayed in the upper left portion of the home screen. Two different modes can be selected: Weight and Pieces. Three different methods to enter the check limits: Over and Under, Nominal Weight Tolerance, or Nominal Percent Tolerance.
  • Page 22: Check Counting

    ® EN-20 RANGER 7000 SCALES To switch between Over/Under Load, Target Weight Tolerance, Target Weight Percentage press the button corresponding to the icon. If desired, edit the value by using the alphanumerical keypad and press the button corresponding to the icon to save the changes and return to the previous screen.
  • Page 23: Application Setup

    ® RANGER 7000 SCALES EN-21 4.3.3 Application Setup The Application can be customized for various user preferences. Press the button corresponding to the icon to enter Configuration Setup The Configuration Menu is now displayed. Select the list item and press the button corresponding to change the setting as desired.
  • Page 24: Input/Output (I/O) Setup

    ® EN-22 RANGER 7000 SCALES Zero Check Zero check is used when comparing subsequent samples to an initial reference sample. In this case, the UNDER limit must be a negative value and the OVER limit must be a positive value. Place the reference item on the scale and press Tare.
  • Page 25: Formulation

    ® RANGER 7000 SCALES EN-23 4.4 Formulation Use this application for compounding and recipe making. The number of components can be 1 to 100. Formulation has two available modes of operation: Free Formulation and Recipe Formulation. Press the button until Formulation is displayed in the upper left portion of the home screen. 4.4.1 Free Formulation (default) This mode of Formulation allows the user to freely add components.
  • Page 26: Recipe Formulation

    ® EN-24 RANGER 7000 SCALES Press the button corresponding to the icon confirm the weight for the current component and to continue adding other components. Notes: To terminate the formulation process, press the button corresponding to the icon. If the added weight is over the tolerance limit, compensation will be performed according to the setup in the configuration (At the end, Off, Immediately).
  • Page 27: Factor And Tolerance Setup

    ® RANGER 7000 SCALES EN-25 Press the button corresponding to the icon or scan a barcode to start formulation. The target weight in each recipe item will be used as preset tare. Place the required weight on the pan (add weight until the displayed value reaches zero again).
  • Page 28: Application Setup

    ® EN-26 RANGER 7000 SCALES 4.4.4 Application Setup The Application can be customized for various user preferences. Press the button corresponding to the icon to enter Configuration The Configuration Menu is now displayed. Select the list item and press the button corresponding to to change the setting as desired.
  • Page 29: Percent Weighing

    ® RANGER 7000 SCALES EN-27 Press the button to enter the Main Menu. With the button corresponding to the icon, go down the list and highlight Application Mode. Enter this sub-menu by pressing the button corresponding to the icon. In the Application Mode menu enter the Formulation sub-menu.
  • Page 30: Establishing A Reference Weight

    ® EN-28 RANGER 7000 SCALES 4.5.1 Establishing a Reference Weight There are three ways to establish a reference weight: 1. Key in the reference weight value using the alphanumerical keypad and then press the button corresponding to the icon. 2. Press the button corresponding to the icon to enter the Edit Reference Weight screen The Edit Reference Weight screen is now displayed.
  • Page 31: Filling

    ® RANGER 7000 SCALES EN-29 The Percent Configurations are defined below (defaults in Bold). Item Available Settings Comments On, Off Auto Tare To enable Automatic Tare On, Off Chain Tare To enable Chain Tare (continuous Tare) Accumulate Off, Automatic, Manual To enter Accumulation / Totalization 4.6 Filling This application allows the user to fill a container to a pre-determined target weight.
  • Page 32: Application Setup

    ® EN-30 RANGER 7000 SCALES 4.6.2 Application Setup The Application can be customized for various user preferences. Press the button corresponding to the icon to enter Configuration The Configuration Menu is now displayed. Select the list item and press the button corresponding to the icon to change the setting as desired.
  • Page 33: Dynamic Weighing

    ® RANGER 7000 SCALES EN-31 Note: The output will be reset to normally open when both SP1 and SP2 are reached. The I/O’s will only work when the I/O Option Board have been installed. See the Accessory list in section 9.4 for information.
  • Page 34: Application Setup

    ® EN-32 RANGER 7000 SCALES The DYNAMIC Home screen Main Display Line Reference Fields Functions Application Icon Note: Refer section 9.5, or press the button for button icon explanation. 4.7.1 Application Setup The Application can be customized for various user preferences. Press the button corresponding to the icon to enter Application Setup...
  • Page 35: Average Time Setup

    ® RANGER 7000 SCALES EN-33 4.7.2 Average Time Setup Press the button corresponding to the icon to enter the Edit Average Time screen The Edit Average Time screen is now displayed. Enter the Average Time by using the alphanumerical keypad and press the button corresponding to the icon to change save the value and return to the Application home...
  • Page 36: Density Determination

    4.8 Density Determination The Ranger 7000 can be used to determine an object’s density. Two types of density determination can be made: 1. Solids more dense than water 2. Solids less dense than water Press the button until Density is displayed in the upper left portion of the home screen.
  • Page 37: Application Setup

    ® RANGER 7000 SCALES EN-35 4.8.1 Application Setup The Application can be customized for various user preferences. Press the button corresponding to the icon to enter Configuration The Configuration Menu is now displayed. Select the list item and press the button corresponding to to change the setting as desired.
  • Page 38 ® EN-36 RANGER 7000 SCALES The Enter Water Temperature screen is now displayed. Enter the water temperature by using the alphanumerical keypad and press the button corresponding to the icon, to save the value and return to the previous screen. Liquid Type: Other Press the button corresponding to the icon to...
  • Page 39: Application Setup

    ® RANGER 7000 SCALES EN-37 4.9.1 Application Setup The Application can be customized for various user preferences. Press the button corresponding to the icon to enter Configuration The Configuration Menu is now displayed. Select the list item and press the button corresponding to to change the setting as desired.
  • Page 40: Sieve Weighing

    ® EN-38 RANGER 7000 SCALES 4.10 Sieve Weighing Sieve analysis (or gradation test) is a practice or procedure used to assess the particle size distribution (also called gradation) of a granular material. It can be performed on any type of non-organic or organic granular materials including sands, crushed rock and aggregates, clays, granite, feldspars, asphalt, concrete, coal, soil, as well as a wide range of manufactured powders, grain and seeds.
  • Page 41: Sieve Operation

    ® RANGER 7000 SCALES EN-39 4.10.2 Sieve Operation To start sieve operation, please follow the instructions below. Recall a sieve set from library to begin. Note: A sieve set must be in library for the sieve application to work. Each Sieve to be used has to be added to the set, even if they are not used for Fineness Modulus calculation, as well as the Pan (with mm size 0).
  • Page 42 ® EN-40 RANGER 7000 SCALES Remove the original weight for processing or shaking. After processing or shaking is completed, press the button corresponding to the icon to begin Sieve analysis. Place container on pan. The scale will then perform an auto tare.
  • Page 43: Library

    ® RANGER 7000 SCALES EN-41 4.11 Library When an item is processed on a regular basis, the item’s data may be stored in memory for future use. This memory is referred to as the Scale’s Library. The following data is stored for the Application used: Sieve Size Preset Ref./Target...
  • Page 44: Retrieving A Library Record

    7000 SCALES Sieve Weighing: Sieves in a set can be entered as a mix of inch, # and mm or cm sizes, but the Ranger 7000 uses mm measurements for all of its calculations. Each individual Sieve can be edited so that the following information is associated with the Sieve: Unit –...
  • Page 45: Additional Features

    Additional Features 4.12.1 Weigh Below The Ranger 7000 Scale is equipped with a weigh below hook for weighing below the scale. CAUTION: Make sure that the scale is properly supported so that it cannot fall or detach during use of the Weigh below feature.
  • Page 46: Main Menu

    ® EN-44 RANGER 7000 SCALES Press the button corresponding to the icon to select the setting. Press the button to return to the previous screen. Press the button or the button corresponding to the icon , to exit the menu mode and return to the last active Application mode.
  • Page 47: Linearity Calibration

    ® RANGER 7000 SCALES EN-45 With the scale turned ON and no load on the pan, start Span Calibration to initiate the procedure. Additional calibration values to be used are shown on the display. The best accuracy is achieved using the mass closest to the full span value. 5.3.4 Linearity Calibration Linearity calibration uses three calibration points, one at zero load and the others at...
  • Page 48: Geo Adjustment

    ® EN-46 RANGER 7000 SCALES 5.3.8 GEO Adjustment Enter this sub-menu to set the GEO values. Press the button corresponding to the icon to adjust the GEO value. Choose the correct GEO value and press the button corresponding to the icon to confirm.
  • Page 49: Power On Unit

    ® RANGER 7000 SCALES EN-47 5.4.4 Power On Unit Set the unit that will be displayed at Power On. Auto Kilogram Pound Gram Ounce Pound:Ounce Custom Unit 5.4.5 Power On Zero Zero the balance at Power On. OFF = disabled. ON = enabled.
  • Page 50: Read Out

    Note: The barcode rule is only functional when connecting a barcode scanner through the USB host. Since there are many brands of Barcode scanners in the market, OHAUS tested and confirmed that below Barcode scanners from Datalogic are compatible with Ranger7000:...
  • Page 51: Stability

    ® RANGER 7000 SCALES EN-49 5.5.2 Stability Set the amount the reading can vary while the stability symbol remains on. 0.5 Division = 0.5 graduations 1 Division = 1 graduation 2 Division = 2 graduations 5 Division = 5 graduations Note: The setting is forced and locked to 1 Division when the Security Switch is set to the locked position.
  • Page 52: Application Mode

    ® EN-50 RANGER 7000 SCALES Application Mode Enter this sub-menu to enable or disable the desired Scale Applications. Only one application can be running at a time. Note: The use of each Application is described in detail in Section 4. 5.6.1 Turning an Application ON/OFF Highlight the application by pressing the buttons...
  • Page 53: Reset

    ® RANGER 7000 SCALES EN-51 5.7.2 Reset To reset the unit settings to factory default settings select Reset and then confirm either Yes or No. 5.7.3 Turning a Unit ON/OFF Select the desired unit, then press the button corresponding to the icon and then choose either On or Off.
  • Page 54: Communication

    ® EN-52 RANGER 7000 SCALES Communication Enter this menu to define external communication methods and to set printing parameters. Data may be output to either a printer or PC (see section 6.5 for output string). Factory default settings are shown in bold. Communication Sub-menu RS232 Choosing an item brings up another menu level (RS232 shown):...
  • Page 55: Reference Balance

    On = connect to reference balance Note: Use reference balance to perform sampling with high resolution balance in Counting Mode. Please make sure the balance is already switched on before connecting to Ranger 7000. Alternate Print Command Set the alternate command character for Print.
  • Page 56 Table 5-1. Non-significant weight data and tare data digits are transmitted as spaces. The continuous output mode provides compatibility with OHAUS products that require real-time weight data. Table 5-1 shows the format for the standard continuous output. Table 5-1: Standard Continuous Output Format...
  • Page 57: Select Template

    ® RANGER 7000 SCALES EN-55 Table 5-4: Status Byte C Bit Definitions Bits 2, 1, and 0 Weight Description lb or kg, selected by Status Byte B, bit 4 grams (g) metric tons (t) ounces (oz) not used not used tons (ton) no units Bit 3...
  • Page 58 ® EN-56 RANGER 7000 SCALES Item Length Item Length 3 spaces String 1 Up to 40 10 spaces String 2 Up to 40 15 spaces String 3 Up to 40 Date String 4 Up to 40 Displayed Weight String 5 Up to 40 Displayed Number String 6...
  • Page 59: Edit String

    Output weighing results directly to a PC application. Setup is easy and no additional software is required. ® Note: Data Transfer Function is not supported in Windows 7/8. OHAUS provides SPDC software for Windows 7/8 users. = do not print. = print the specified settings.
  • Page 60: User Profiles

    ® EN-58 RANGER 7000 SCALES 5.10 User Profiles Create users with user name and password. User Screen Functions The User profile is used for saving user specific parameters in menu Total 50 user profiles can be saved in file system User name max length: 12 Password max length: 6 User authorities...
  • Page 61 ® RANGER 7000 SCALES EN-59 To login as Adminstrator press the button corresponding to the icon . A login screen is displayed with a password field. Enter the password associated with the account. If the wrong password is entered, an error screen will be displayed. Press the button correpsonding to the icon to return to the login screen.
  • Page 62: Memory

    ® EN-60 RANGER 7000 SCALES Press the button corresponding to the icon to delete the user permanently or to cancel the deletion and return to User Profiles main screen. 5.11 Memory 5.11.1 USB memory USB memory is used to store the weight readings for future reference. In the USB memory menu, set the status to On to enable this feature.
  • Page 63 ® RANGER 7000 SCALES EN-61 The latest record is always displayed on top. Use the buttons corresponding to the icons and to move up and down the list. Press the button corresponding to the icon to locate a record by entering it’s ID No. Press the button corresponding to the icon to print a range of records.
  • Page 64 ® EN-62 RANGER 7000 SCALES still attached with the Terminal main PCBA. STEP 2. Insert the Alibi Memory board into the slot as shown below; making sure the pins and supporting plastic leg are all properly inserted. 1.800.561.8187 information@itm.com www. .com...
  • Page 65: Maintenance

    ® RANGER 7000 SCALES EN-63 5.12 Maintenance Export Export User Import Import User Library Profile Library Profile Drives Note: The import/export is only functional when the current user is administrator. Maintenance Sub-menu 5.12.1 Export Library Export Library to USB flash drive. 5.12.2 Export User Profile Export Export User Profile to USB flash drive.
  • Page 66: Serial Communication

    Interface Commands The scale supports both MT-SICS and OHAUS commands. Commands listed in the following tables will be acknowledged by the scale. To use the MT-SICS commands, send the command PSI. To return to the OHAUS commands, send the command POH.
  • Page 67: Rs232 Interface

    ® RANGER 7000 SCALES EN-65 Command Function LEVEL 2 Calibrate with the external calibration weight Calibrate with the internal calibration weight Inquire or set scale ID Inquire of scale type P100 Print out on the printer Print out stable weight value P101 P102 Print out current weight value immediately...
  • Page 68: Connecting To A Computer

    USB Host USB Device The Ohaus USB Device Interface is a unique solution to the problem of connecting a scale to a computer using a Universal Serial Bus (USB). USB devices are categorized into classes such as disk drives, digital cameras, printers, etc.
  • Page 69: Virtual Port Software Installation

    This can be done in the Port Settings of the Device Manager utility, found in the Windows Control Panel. USB Host The USB Host can be used to connect a barcode scanner and USB flash drive to the Ranger 7000. Printout Format...
  • Page 70: Printout Examples

    Note: The Termination Characters Carriage Return and Line Feed are appended to the printout. Printout Examples Setup in Menu Print out {String 1} {New Line} OHAUS CORPORATION {String 2} {New Line} 7 Campus Drive {String 3} {New Line} Suite 310...
  • Page 71: Legal For Trade

    ® RANGER 7000 SCALES EN-69 String 9: ************************ String 10: OHAUS Corporation Size Acc. % retained String 11: 7 Campus Drive Ste 310 69.96% String 12: Parsippany NJ 07054 20mm 92.23% String 13: www.ohaus.com 1.800.672.7722 100.00% String 15: User ID:...
  • Page 72: Maintenance

    ® EN-70 RANGER 7000 SCALES MAINTENANCE Calibration Periodically verify calibration by placing an accurate weight on the scale and viewing the result. If calibration is required, perform as explained in section 5. Information Information is available from any application and is accessed by pressing the button.
  • Page 73: Cleaning

    Service Information If the troubleshooting section does not resolve your problem, contact an Authorized Ohaus Service Agent. Please visit our website www.ohaus.com to locate the Ohaus office nearest you. An Ohaus Product Service Specialist will be available to assist you.
  • Page 74: Technical Data

    ® EN-72 RANGER 7000 SCALES TECHNICAL DATA Specifications Ambient conditions  Indoor use only  Altitude: Up to 2000 m  Specified Temperature range: 10 ° C to 30 ° C (R71MHD3/6/15/35 models) -10 ° C to 40 ° C (R71MD3/6/15/35 models) ...
  • Page 75: Drawings And Dimensions

    665 x 525 x 330 mm Shipping dimensions 23.8 x 15.9 x 9.6 inch 26.2 x 20.7 x 13 inch Drawings and Dimensions Fully assembled dimensions A. Large base B. Small Base Figure 9-1. Ranger 7000 dimensions 1.800.561.8187 information@itm.com www. .com...
  • Page 76: Table Of Geo Values

    ® EN-74 RANGER 7000 SCALES Table of Geo Values For weighing instruments verified by the manufacturer, the geo value indicates the country or geographical zone for which the instrument is verified. The Geo value set in the instrument (e.g."Geo 18") appears briefly after switch-on or is specified on a label.
  • Page 77: Options

    ® RANGER 7000 SCALES EN-75 Options TABLE 9-4. OPTIONS DESCRIPTION PART NUMBER Rechargeable Battery Kit, EX HiCap, R71 30041295 Accessory Tower Kit, R71 30095408 Accessory RS232, Kit, R31, RC31, V71, R71 30037448 Accessory 2 Platform Kit, R71 30097590 Accessory Discrete I/O, R71 30097591 Accessory Ethernet Kit, R31, RC31, V71, R71 30037447...
  • Page 78: Button Icons List

    ® EN-76 RANGER 7000 SCALES Button Icons List TABLE 9-5. BUTTON ICONS WEIGHING APPLICATION ICON FUNCTION ICON FUNCTION Edit selected record (used in Setup Weighing mode configurations Library) Recall selected record (used in Manual Accumulation Library) Delete selected record (used in Quit (Used in Library) Library) Add a record (used in Library)
  • Page 79 ® RANGER 7000 SCALES EN-77 TABLE 9-5. BUTTON ICONS (Continued) DENSITY APPLICATION ICON FUNCTION ICON FUNCTION Enter liquid density Setup Density mode configurations Accept current weight Start Set water temperature Cancel FILLING APPLICATION ICON FUNCTION ICON FUNCTION Switch the Setpoints' input Setup Filling mode configurations method Set input value or current weight on...
  • Page 80 ® EN-78 RANGER 7000 SCALES TABLE 9-5. BUTTON ICONS (Continued) DIFFERENTIAL APPLICATION ICON FUNCTION ICON FUNCTION Setup Differential mode Accept current weight configurations Edit Items Reset PERCENT APPLICATION ICON FUNCTION ICON FUNCTION Setup Percent mode configurations Manual Accumulation Set reference weight FORMULATION APPLICATION ICON FUNCTION...
  • Page 81 ® RANGER 7000 SCALES EN-79 ICON FUNCTION ICON FUNCTION Guest Print Range Login Locate Alibi record SIEVE APPLICATION ICON FUNCTION ICON FUNCTION View selected record (Used in Setup Sieve mode configurations Library) Edit record Name (Used in Manually input start weight Library) Delete selected record (Used Start...
  • Page 82: Compliance

    This Class A digital apparatus complies with Canadian ICES-001. ISO 9001 Registration In 1994, OHAUS Corporation, USA, was awarded a certificate of registration to ISO 9001 by Bureau Veritus Quality International (BVQI), confirming that the OHAUS quality management system is compliant with the ISO 9001 standard’s requirements.
  • Page 83 Should this device be passed on to other parties (for private or professional use), the content of this regulation must also be related. Disposal instructions in Europe are available online at www.ohaus.com/weee. Thank you for your contribution to environmental protection.
  • Page 84 Ohaus. In lieu of a properly returned warranty registration card, the warranty period shall begin on the date of shipment to the authorized dealer. No other express or implied warranty is given by Ohaus Corporation. Ohaus Corporation shall not be liable for any consequential damages.