H
1 time
H
2 times
H
3 times
H
4 times
H
5 times
H
6 times
H
7 times
H
1 time
H
2 times
H
3 times
H
4 times
H
5 times
H
6 times
H
1 time
H
2 times
H
3 times
H
5 times
Table 10—Indoor Unit Error Display
DISPLAY
X
E0
Indoor unit EEPROM parameter error
X
E1
Indoor / outdoor units communication error
X
E2
Zero-crossing signal detection error
X
E3
Indoor fan speed has been out of control
X
E4
Indoor room temperature sensor T1 open circuit or short circuit
X
E5
Evaporator coil temperature sensor T2 open circuit or short circuit
X
EC
Refrigerant leakage detection
O
F0
Overload current protection
O
F1
Outdoor ambient temperature sensor T4 open circuit or short circuit
O
F2
Condenser coil temperature sensor T3 open circuit or short circuit
O
F3
Compressor discharge temperature sensor T5 open circuit or short circuit
O
F4
Outdoor unit EEPROM parameter error
O
F5
Outdoor fan speed has been out of control
H
P0
IPM malfunction or IGBT over-strong current protection
H
P1
Over voltage or over low voltage protection
High temperature protection of compressor top diagnosis and solution (only for
H
P2
9k,12k models)
H
P4
Inverter compressor drive error
O(light)