Light Path Diagnostics Leds - IBM BladeCenter HS20 8843 Installation And User Manual

Eserver
Hide thumbs Also See for BladeCenter HS20 8843:
Table of Contents

Advertisement

Light path diagnostics LEDs

The following table lists the LEDs on the light path diagnostics panel, the problems
that they indicate, and actions to solve the problems. The following illustrations
show the light path diagnostics panel and LEDs on the system board.
Light path diagnostics panel
DIMM 1 error LED
(CR6)
DIMM 2 error LED
(CR5)
DIMM 3 error LED
(CR4)
DIMM 4 error LED
(CR201)
Power is available to relight the light path diagnostics LEDs for a small period of
time after the blade server is removed from the BladeCenter unit. During that period
of time, you can relight the light path diagnostics LEDs for a maximum of 25
seconds (or less, depending on the number of LEDs that are lit and the length of
time the blade server is removed from the BladeCenter unit) by pressing the light
path diagnostics button. The light path diagnostics power present LED (CR111) is lit
when the light path diagnostics button is pressed if power is available to relight the
blade-error LEDs. If the light path diagnostics power present LED is not lit when the
light path diagnostics button is pressed, no power is available to light the
blade-error LEDs, and they will be unable to provide any diagnostic information.
64
Eserver BladeCenter HS20 Type 8843: Installation and User's Guide
NMI
NMI error LED
MIS
Microprocessor speed mismatch error LED
SBRD
System-board error LED
TEMP
Over temperature error LED
Light path diagnostics LED (CD111)
Light path diagnostics switch (SW4)
Microprocessor 1 error LED (CR12)
Microprocessor 2 error LED (CR13)
System board fault LED (CR30)
BMC fault LED (CR111)

Advertisement

Table of Contents
loading

Table of Contents