synergy
Quick Start Guide
Type
le A
kW at 400V
SGY-101
17
7.5
SGY-103
22
11
SGY-105
29
15
SGY-107
35
18.5
SGY-109
41
22
SGY-111
55
30
SGY-113
66
37
SGY-115
80
45
SGY-117
100
55
Ie AC-53a:3.5-17:90-5
HPat 440-
UL.FLA A
480V
17
10
21
15
27
20
34
25
40
30
52
40
65
50
77
60
96
75
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the Synergy SGY-101 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fairford Synergy SGY-101

  • Page 1 synergy ™ Quick Start Guide HPat 440- Type le A kW at 400V UL.FLA A 480V SGY-101 SGY-103 SGY-105 SGY-107 18.5 SGY-109 SGY-111 SGY-113 SGY-115 SGY-117 Ie AC-53a:3.5-17:90-5...
  • Page 2 Redefining Motor Control As the original pioneers of soft start technology Fairford Electronics Ltd have been at the forefront of motor control innovation since the 1970’s. A major designer and manufacturer of soft start motor control solutions Fairford have manufactured and supplied over 1 million products into the market place and are recognised as the reference point for many control solution providers worldwide.
  • Page 3 Environment - installation Dimensions Fitting 95mm (3¾”) 95mm (3¾”) 25mm (1”) 25mm (1”) 25mm (1”) 60mm 60mm 176mm (6 ⁄ ”) 176mm (6 ⁄ ”) (2 ⁄ ”) (2 ⁄ ”) Weight = 3.5kg SECTION A-A Enclosure Ventilation When fitting synergy into a cabinet, ventilation must be provided if the heat output of the unit is greater than the cabinet will dissipate.
  • Page 4 Wiring connection...
  • Page 5 Wiring connection In Line In Delta K1 - Main contactor and protection switch gear K1 - Main contactor or (provided by the customer) circuit breaker isolation and protection switch gear For this configuration (provided by the customer) applying the equation. synergy™...
  • Page 6 Programmes Please note; Only appears if application with a trip class higher than 10 is selected...
  • Page 7 Rating table 220- 440- Type 230v 400v 200v 208v SGY-101 SGY-103 SGY-105 SGY-107 18.5 SGY-109 SGY-111 SGY-113 18.5 SGY-115 SGY-117 • Rated operational powers in kW according to IEC 60072-1(primary series) corresponding to IEC current rating optimised for 400V • Rated operational powers in hp according to UL508 corresponding to FLA current rating(optimised for 440-480v) •...
  • Page 8 Technical information Motor overload 'cold' trip curves (20°C ambient) 1000   100   10   1   1   1.5   2   2.5   3   3.5   4   4.5   Multiple of Motor FLA Class10   Class20   Class30  ...
  • Page 9 Technical information/Standards Rated operational voltages 230Vac to 480Vac Rated operational current See model ratings table below Rating index : AC-53a:3.5-17: 90-5 Rated frequency/frequencies 45 to 65Hz Rated duty Uninterrupted Form designation Form 1 Internally bypassed Rated insulation voltage 480V Main circuit Rated impulse withstand voltage Control supply circuit...
  • Page 10 Standards -20°c (-4°f) to 50°c (122°f) above 50°c de-rate by 2% per degree to a maximum of 60°c (140°f). Maximum altitude above sea level 1000m (3281ft) above 1000m de rate by 1% per 100m (328ft) to a maximum altitude of 2000m (6562ft). Please note for higher temperatures and altitudes contact your supplier.
  • Page 11 Notes...
  • Page 12 Livsfara genom elektrisk ström! Toate lucrările descrise trebuie efectuate numai de personal de specialitate calificat şi Endast utbildade elektriker och personer som undervisats i elektroteknik får utföra de arbeten de persoane cu cunoştiinţe profunde în electrotehnică. som beskrivs nedan. info@fairford.com www.fairford.com...