Resetting the converter
1. Cut the current (can be done using the on/off, emergency stop switches or by disconnecting the contact)
2. Wait about one minute until the converter has gone out
3. Switch off the current
Overloading the grinder is a common fault. There are three levels of overload
1. OCF
2. OHF
3. OLF
Things to remember.
The grinder will not start if the front/back position is engaged when the power supply is applied
Check the latest error code
1.
Keep ESC pressed in until 4 dashes appear ----.
2.
When rdy (ready) appears, press ENTER.
3.
SET is displayed. Press the down arrow until you come to SUP.
4.
Press ENTER. FrH is now displayed.
5.
Press the down arrow until you see LFt (8 times) Press ENTER.
.
The last error code is displayed.
3