DO NOT TURN ON THE POWER UNLESS THE REMOTE UNIT(S)
ARE CONNECTED TO ANTENNAS OR ATTENUATORS ON THE
3.1

Automatic Set-up:

3.1.1 Hub Set-up:
Connect the computer using an RS232 serial port with a DB9 male connector (on
cable end for the repeater) to the hub status and control module in the repeater.
Use a terminal emulation program, such as ProComm or HyperTerminal, set to:
VT-100 series terminal emulation
9600 baud
8 bit
1 stop bit
no parity
no flow control (flow control = none)
Turn the hub on, followed by each remote unit. Press the 'Enter' key on the
computer to initialize the login screen.
Note: Login may take several seconds if the repeater is in active communications
mode. To bypass sending all of the alarms, press 'ENTER' as soon as the date and
time appear on the screen.
Note: For assistance, type 'HELP' for a list of available commands.
Login to the system using one of the default Usernames and Passwords shown in Table
1 below. Both the Username and Password are CASE SENSITIVE. Do not use the
number pad on the keyboard to input numbers