Dual fuel portable generator: gasoline: 3600 running watts - 4650 peak watts; propane: 3240 running watts - 4180 peak watts
Hide thumbs Also See for WGen3600DF:

Advertisement

USER MANUAL
REMOTE START
PUSH BUTTON
ELECTRIC START
W
Gen3600DF
Dual Fuel Portable Generator
GASOLINE: 3600 Running Watts | 4650 Peak Watts
PROPANE: 3240 Running Watts | 4180 Peak Watts

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WGen3600DF and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Westinghouse WGen3600DF

  • Page 1 USER MANUAL REMOTE START PUSH BUTTON ELECTRIC START Gen3600DF Dual Fuel Portable Generator GASOLINE: 3600 Running Watts | 4650 Peak Watts PROPANE: 3240 Running Watts | 4180 Peak Watts...
  • Page 2: Save These Instructions

    A decrease in engine horsepower will decrease the power output of the generator. Contact our service team to order altitude kits. See page 16 for altitude kit numbers. HAVE QUESTIONS? DO NOT RETURN THIS PRODUCT TO THE STORE Email us at service@wpowereq.com or call 1-855-944-3571 2 | Westinghouse Portable Power...
  • Page 3: Product Registration

    IMPORTANT: KEEP YOUR PURCHASE RECEIPT TO ENSURE TROUBLE-FREE WARRANTY COVERAGE. PRODUCT REGISTRATION To ensure trouble-free warranty coverage, it is important you register your Westinghouse generator. You can register your generator by either: 1. Filling in the product registration form below and mailing to:...
  • Page 4 Installing Wheels and Feet ....11 WGen3600DF Engine View ....32 Installing the Battery .
  • Page 5: Safety

    NOTE: Indicates a procedure, practice or condition that should be followed in order for the generator to function in the manner intended. Westinghouse Portable Power | 5...
  • Page 6: General Safety Rules

    Never use the generator to power medical support engine misfires often. equipment. Always disconnect tools or Always remove any tools or other service equipment used appliances from the during maintenance from the generator before operating. generator before starting. 6 | Westinghouse Portable Power...
  • Page 7: Safety Labels And Decals

    Columbus Ohio 43228 USA Numéro de contrat MWE Investments LLC Designed in Columbus , Ohio USA principa l de CSA Columbus Ohio 43228 Etats-Unis Co n u à columbus , Ohio,tats-Unis Made in China/ Fabriqu é en Chine Westinghouse Portable Power | 7...
  • Page 8 SAFETY SAFETY LABELS AND DECALS 8 | Westinghouse Portable Power...
  • Page 9: Fuel Safety

    • Make sure the generator and propane tank are on a flat surface before operating. • If there is a propane odor do not start the unit because there may be a potential leak. • Never place propane tank near engine exhaust. Westinghouse Portable Power | 9...
  • Page 10: Unpacking

    Wheel Kit Accessories Box Funnel (1) WHEEL KIT ACCESSORIES BOX Open the Wheel Kit Accessories box and verify the contents against the list right. If any parts are missing, contact our service team at service@wpowereq.com or call 1-855-944-3571. 10 | Westinghouse Portable Power...
  • Page 11: Assembly

    4. Repeat previous steps on other wheel. 3. Install the mounting foot to the frame using M8 flange bolts. 1 - Mounting Feet 2 - Flange Bolts M8 Figure 1 - Assemble Mounting Feet to Frame Westinghouse Portable Power | 11...
  • Page 12: Installing The Battery

    Even if you do not plan on using the electric start feature it is recommended that you install the battery to complete the circuit in order for the automatic choke mechanism to work properly. Figure 4 - (1) Negative Cable 12 | Westinghouse Portable Power...
  • Page 13: Features

    Battery: Included for electric start models. Air Filter: Rotate knob to unlock air cleaner cover for easy access. Oil Fill Plug/Dipstick: Must be removed to add and check oil. Westinghouse Portable Power | 13...
  • Page 14 CARB Canister: Required for models sold into and used in California. Muffler and Spark Arrester: Avoid contact until engine is cooled down. Spark arrestor prevents sparks from exiting the muffler. It must be removed for servicing. 14 | Westinghouse Portable Power...
  • Page 15: Control Panel Features

    Battery Indicator Light: When light is illuminated, the current that can be delivered through the 120- the battery is connected. volt duplex outlets to 20amps. Ground Terminal: The ground terminal is used to ground the generator. Westinghouse Portable Power | 15...
  • Page 16: Operation

    High Altitude Carburetor Kit Part Number: 140543 • Block cooling vents High Altitude DF Regulator Part Number: 140560 • Block air intake system Note: You must purchase the Dual Fuel Regulator along with carburetor kit on the WGen3600DF 16 | Westinghouse Portable Power...
  • Page 17: Power Cord

    Using Extension Cords Westinghouse Portable Power assumes no responsibility for the content within this table. The use of this table is the responsibility of the user only. This table is intended for reference only. The results produced by using this table are not guaranteed to be correct or applicable in all situations as the type and construction of cords are highly variable.
  • Page 18: Engine Fluids And Fuel

    5. Press and hold the REMOTE PAIRING button for 3 seconds. The generator is now programmed to Weather will affect engine oil performance. Change the type of engine oil used based on weather conditions to suit the engine start remotely needs. 18 | Westinghouse Portable Power...
  • Page 19: Adding Gasoline To The Fuel Tank

    This may result in explosion hazard. Do not use provided LPG hose for any other appliances. Avoid prolonged breathing of gasoline vapors. Always turn off the propane tank and disconnect LPG hose when not in use. Westinghouse Portable Power | 19...
  • Page 20: Switching Fuel Sources

    If frost becomes an issue try exchanging fuel tanks to allow the first tank to warm up. You can also temporarily warm the tank up by pouring warm water over the top of the propane tank. 20 | Westinghouse Portable Power...
  • Page 21: Starting The Generator

    • The red engine stop button can be pushed at any time during the automatic start sequence to abort the engine start attempt. Westinghouse Portable Power | 21...
  • Page 22: Stopping The Generator

    Always perform maintenance in a well- Allow hot components to cool to ventilated area. Gasoline fuel and fuel the touch prior to performing any vapors are extremely flammable and maintenance procedure. can ignite under certain conditions. 22 | Westinghouse Portable Power...
  • Page 23: Maintenance

    Spark Plug Check/Clean Replace Spark Arrestor Check/Clean *Service more frequently if operating in dry and dusty conditions TABLE 2: MAINTENANCE SCHEDULE - AUTHORIZED WESTINGHOUSE SERVICE DEALER PERFORMED After First 20 After 50 Hours After 100 Hour After 300 Hours Before Every...
  • Page 24: Engine Oil Maintenance

    Stop frequently to check the level to avoid overfilling. 8. Continue to add oil until the oil is at the correct level. See Figure 19. Figure 18 - Oil Fill Plug/Dipstick 24 | Westinghouse Portable Power...
  • Page 25: Changing Engine Oil

    NEVER twist or tear the foam air filter element during cleaning or drying. Only apply slow but firm squeezing action. 6. Rinse in clean water by submerging the air filter elements in fresh water and applying a slow squeezing action Westinghouse Portable Power | 25...
  • Page 26: Spark Plug Maintenance

    Torch: F7TC Never apply any side load or move the spark plug laterally when removing the spark plug. Applying a side load or moving the spark plug laterally may crack and damage the spark plug boot. 26 | Westinghouse Portable Power...
  • Page 27: Checking And Adjusting Valve Lash

    Proper care should be taken to prepare the generator for 7. Turn the adjusting nut to obtain the correct valve any storage. lash. When the valve lash is correct, hold the ad- justing nut and tighten the jam nut to 106 in-lb (12 N•m). Westinghouse Portable Power | 27...
  • Page 28: Trouble Shooting

    3. Restart the generator and reduce the load. stops running. 4. If trying 1-3 above does not solve the 4. Take the generator to your nearest problem,the cause might be a fault in the authorized service dealer. generator. 28 | Westinghouse Portable Power...
  • Page 29: Troubleshooting

    Move the fuel selector valve to propane. Turn the gasoline fuel valve to off. Start the engine and allow the engine to run until the fuel has been consumed in the carburetor. Begin propane start up procedure. Westinghouse Portable Power | 29...
  • Page 30: Wgen3600Df Exploded View

    WGen3600DF EXPLODED VIEW 30 | Westinghouse Portable Power...
  • Page 31 WGen3600DF EXPLODED PART NO. Part. Description 120521 M6X165 100544 Handle Cover 100608 Frame 150545 Hose Clamp 100593 Fuel Filter 105560 Damper 150550 Hose Clamp 130539 Fuel Selector Knob 100559 Damper 120537 M5X12 100594 High Pressure 100520 M8 Nut 120529 Regulator...
  • Page 32: Wgen3600Df Engine View

    180538 Starter Cup 140557 Stepper Motor 140516 Gasket 180537 Crankshaft Nut Coupling Shaft 180571 M10X80 Stud 180599 Ignition Coil Assy 140558 Stepper Motor 140552 Carburetor Assy 100518 M6X25 Fastener 140553 Fuel Hose 140514 Spacer 140559 Stepper Motor 32 | Westinghouse Portable Power...
  • Page 33: Schematics

    WGen3600DF SCHEMATIC Westinghouse Portable Power | 33...
  • Page 34 MAINTENANCE NOTES 34 | Westinghouse Portable Power...
  • Page 35 MAINTENANCE NOTES Westinghouse Portable Power | 35...
  • Page 36 Version 9.25.17KD 36 | Westinghouse Portable Power...