Testing Power Component - AEG 88101 Service Manual

Induction hobs
Table of Contents

Advertisement

3 Testing Power Component

1. When alarm messages and disabled zones exist ("E" in cooking phase display), please make
a note of the power component which is affected.
2. (7) Check whether the lead from the filter board is connected, also check the bus lines (6)
µprocessors filter to power component.
3. If (8) IGBT has become shorted, this normally means that the IGBT housing is damaged.
Replace power component
4. (8) Measure resistance at the IGBTs
Pin1-Pin2 or Pin2-Pin3
Only replace the affected power component and (9) insert 20A fuse, completely separate the
fuse strip conductor.
S12 = right power component
S11 = left power component
5. By a short-circuit and destroyed power component, it is imperative that the coil lines be
inspected for signs of damage.
6. Also replace the filterboard should the replacement of the power component not succeed.
(6)
(7)
DGS-TDS
21.04.08
15
>50kOhm
Okay
<50Ohm
power component defect & replace
599 519 523 EN
(9)
(7)
(6)
(8) 8 St.
IGBT
Pin 1 2 3