If there is a danger of a serious accident resulting from a failure or a defect in this unit, provide the unit
with an appropriate external protective circuit to prevent an accident.
•
The unit is normally supplied without a power switch and fuses.
Make wiring so that the fuse is placed between the main power supply switch and this controller.
(Main power supply: 2 pole breaker, fuse rating: 250V, 1A)
•
When wiring the power supply terminal, use vinyl insulated 600 volt cable or equivalent.
•
To avoid the damage and failure of controller, supply the power voltage fitting to the rating.
•
To avoid an electric shock and controller failure, do not turn ON the power before all wiring is com-
pleted.
•
Be sure to check that the distance is kept to avoid electric shock or firing before turning the power ON.
•
Keep away from terminals while the circuit is energized in order to avoid an electric shock and a
malfunction.
•
Never attempt to disassemble, fabricate, modify, or repair this unit because tampering with the unit
may result in a malfunction, electric shock, or a fire.
1.2 Maintenance precautions
•
Be sure to turn off the power before this controller is installed or removed in order to avoid an electric
shock, malfunction, and fault.
•
Regular maintenance is recommended a longer service life of this controller.
Some parts of this controller have a limited life span, or they will be deteriorated with the lapse of time.
•
One-year warranty is guaranteed for this unit including accessories, provided that the controller is
properly used.
– 5 –