  • Page 1 308 · Smoke tester Instruction manual...
  • Page 2 0970 3080 en 01 testo AG...
  • Page 3: Table Of Contents

    1 Contents Pos: 1 /TD/Überschriften/1. Inhalt @ 0\mod_1177587817070_79.doc @ 1243 Contents Contents .....................3 Safety and the environment ..............5 2.1. About this document ..............5 2.2. Ensure safety ................6 2.3. Protecting the environment ............7 Specifications..................8 3.1..................8 3.2. Technical data................8 Product description .................10 First steps..................12 5.1.
  • Page 4 1 Contents Tips and assistance .................25 8.1. Questions and answers ............25 8.2. Accessories and spare parts............26 8.3. Service information ..............27 Pos: 2 /TD/--- Seitenwechsel --- @ 0\mod_1173774430601_0.doc @ 283 0970 3080 en 01 testo AG...
  • Page 5: Safety And The Environment

    2 Safety and the environment Pos: 3 /TD/Überschriften/2. Sicherheit und Umwelt @ 0\mod_1173774719351_79.doc @ 292 Safety and the environment Pos: 4 /TD/Überschriften/2.1 Zu diesem Dokument @ 0\mod_1173775252351_79.doc @ 346 2.1. About this document Pos: 5 /TD/Sicherheit und Umwelt/Zu diesem Dokument/Verwendung (Standard) @ 0\mod_1173775068554_79.doc @ 337 >...
  • Page 6: Ensure Safety

    Follow the prescribed steps exactly. Use only original spare parts from Testo. Pos: 12 /TD/Sicherheit und Umwelt/Sicherheit gewährleisten/Akku-Sicherheitshinweise (LiIon) @ 0\mod_1187184666109_79.doc @ 2363 > Improper use of the rechargeable battery can lead to destruction or injuries by means of current surges, fire or escaping chemicals.
  • Page 7: Protecting The Environment

    > At the end of its useful life, send the product to the separate collection for electric and electronic devices (observe local regulations) or return the product to Testo for disposal. Pos: 15 /TD/--- Seitenwechsel --- @ 0\mod_1173774430601_0.doc @ 283...
  • Page 8: Specifications

    The digital smoke tester is a hand-held instrument for determining the smoke number of oil firing installations. These systems can be monitored using the testo 308 and checked for compliance with the applicable limit values. The measuring instrument is approved for measurements under the First Federal Immission Control Ordinance (1.
  • Page 9 3 Specifications Characteristic Values Warranty 2 years, warranty conditions: See guarantee card EU Directive 2004/108/EC 1st Federal Immission Control Ordinance Standards/Tests (German ordinance) Pos: 21 /TD/--- Seitenwechsel --- @ 0\mod_1173774430601_0.doc @ 283 0970 3080 en 01...
  • Page 10: Product Description

    4 Product description Pos: 22 /TD/Überschriften/4. Produktbeschreibung @ 0\mod_1173774846679_79.doc @ 310 Product description Pos: 23 /TD/Produktbeschreibung/Übersicht/testo 308/Anzeige- und Bedienelemente @ 0\mod_1176813221481_79.doc @ 833 Display and control elements 1 IR/IrDA interface 2 Gas outlet 3 Display. Instrument status icons: Icon Significance...
  • Page 11 4 Product description 4 Control keys: Function Switching the instrument on/off Left function key: Function changes depending on the instrument status: [Start] Begin smoke measurement [Ok] Accept setting/reading Oil derivative present [set] Open configuration menu Right function Function changes depending on the key: instrument status: Begin leakage test...
  • Page 12: First Steps

    5 First steps Pos: 25 /TD/Überschriften/5. Erste Schritte @ 0\mod_1173774895039_79.doc @ 319 First steps Pos: 26 /TD/Erste Schritte/testo 308/Akku laden @ 0\mod_1177413427960_79.doc @ 1210 5.1. Charging the battery Fully charge the rechargeable battery before using the instrument. The rechargeable battery can only be charged at an ambient temperature of 0 to 35°C / 32 to 95°F.
  • Page 13: Connecting The Mains Unit

    5 First steps Pos: 27 /TD/Erste Schritte/testo 308/Netzteil anschließen @ 0\mod_1177413775799_79.doc @ 1219 5.2. Connecting the mains unit If the mains unit is connected, the instrument is powered automatically via the mains unit. It is not possible to charge the battery in the instrument during operation.
  • Page 14 The instrument has an automatic switch-off function. 10 minutes after the last button was pressed, the instrument switches itself off to protect the rechargeable battery. Pos: 29 /TD/--- Seitenwechsel --- @ 0\mod_1173774430601_0.doc @ 283 0970 3080 en 01 testo AG...
  • Page 15: Using The Product

    6 Using the product Pos: 30 /TD/Überschriften/6. Produkt verwenden @ 0\mod_1173774928554_79.doc @ 328 Using the product Pos: 31 /TD/Produkt verwenden/testo 308/Dichtigkeitstest durchführen @ 0\mod_1195830451218_79.doc @ 5923 6.1. Performing the leakage test The leakage test was started, see Switching the instrument on/off Page 13.
  • Page 16: Measuring

    Pos: 34 /TD/Überschriften/6.3 Messungen durchführen @ 0\mod_1184584650078_79.doc @ 1872 6.3. Measuring Pos: 35 /TD/Produkt verwenden/testo 308/Messungen durchführen @ 0\mod_1193040408187_79.doc @ 5573 > Check the fill level of the condensate trap. Empty this if the max. marking is exceeded, see Emptying the condensate trap Page 19.
  • Page 17 6 Using the product The smoke tester automatically stops as soon as 1.63 reference litres of flue gas have been sucked in. The evaluation of the blackening mark created on the filter paper is performed. The detected smoke number is shown. 3.
  • Page 18: Printing The Measurement Results

    A measurement was performed and lights up. > Request the data from another Testo measuring instrument with the testo 308. Please refer to the documentation for the respective Testo measuring instrument for this. The data transfer takes place by Bluetooth, as long as both instruments have this interace.
  • Page 19: Maintaining The Product

    7 Maintaining the product Pos: 40 /TD/Überschriften/7. Produkt instand halten @ 0\mod_1173789831362_79.doc @ 397 Maintaining the product Pos: 41 /TD/Produkt instand halten/testo 308/Kondensatfalle leeren @ 0\mod_1177416851747_79.doc @ 1228 7.1. Emptying the condensate trap Caution! Damage to the smoke tester by means of condensate entering the gas path.
  • Page 20: Changing The Battery

    7 Maintaining the product Pos: 42 /TD/Produkt instand halten/testo 308/Akku wechseln @ 0\mod_1177412872617_79.doc @ 1201 7.2. Changing the battery 1. Isolate the instrument from the mains and switch it off before changing the rechargeable battery. 2. Open the lock of the service lid (1).
  • Page 21: Changing The Filter Paper

    7 Maintaining the product Pos: 43 /TD/Produkt instand halten/testo 308/Filterpapier wechseln @ 0\mod_1193051672843_79.doc @ 5583 7.3. Changing the filter paper Caution! Damage to or contamination of the measuring lens. > Keep the paper rolls free of contamination, as this could potentially be transmitted to the measuring lens.
  • Page 22 Caution! Damage to the instrument. > Do not pull the filter paper out of the instrument when the service lid is closed. > Only pull the paper sideways in order to tear it off. 0970 3080 en 01 testo AG...
  • Page 23: Replacing The Particle Filter

    7 Maintaining the product Pos: 44 /TD/Produkt instand halten/testo 308/Partikelfilter wechseln @ 0\mod_1195635723421_79.doc @ 5853 7.4. Replacing the particle filter 1. Isolate the instrument from the mains and switch it off before changing the particle filter. 2. Disconnect the instrument plug of a connected mains unit from the instrument.
  • Page 24: Cleaning The Instrument

    7 Maintaining the product Pos: 45 /TD/Produkt instand halten/testo 308/Gerät reinigen @ 0\mod_1196170437015_79.doc @ 5943 7.5. Cleaning the instrument Housing > If the housing of the instrument is dirty, clean it with a damp cloth. Do not use any aggressive cleaning agents or solvents! Weak household cleaning agents and soap suds may be used.
  • Page 25: Tips And Assistance

    Tips and assistance Pos: 49 /TD/Überschriften/8.1 Fragen und Antworten @ 0\mod_1177402017078_79.doc @ 1093 8.1. Questions and answers Pos: 50 /TD/Tipps und Hilfe/Fragen und Antworten/testo 308 @ 0\mod_1193059333062_79.doc @ 5592 Question Possible causes/solutions lights up The measured smoke number is less than 0. The filter paper was contaminated before the measurement.
  • Page 26: Accessories And Spare Parts

    27 or look up our website: www.testo.com Pos: 51 /TD/Überschriften/8.2 Zubehör und Ersatzteile @ 0\mod_1177402058734_79.doc @ 1102 8.2. Accessories and spare parts Pos: 52 /TD/Tipps und Hilfe/Zubehör und Ersatzteile/testo 308 @ 0\mod_1176810317388_79.doc @ 818 Description Article no. Mains unit...
  • Page 27: Service Information

    Tel. (3) 98 00 46 77, Fax (3) 98 00 46 99 E-mail: info@testo.com.au The most up-to-date address details of our subsidiaries and agencies can be found in Internet at: www.testo.com ===== Ende der Stückliste ===== 0970 3080 en 01...