TESTO 645 Instruction Manual
Hide thumbs Also See for 645:

Advertisement

testo 445 · testo 645
Instruction manual
en
Testo-Direct
info@Testo-Direct.com
1.888.610.7664
www.
.com

Advertisement

Table of Contents
loading

Summary of Contents for TESTO 645

  • Page 1 445 · testo 645 Instruction manual Testo-Direct info@Testo-Direct.com 1.888.610.7664 www. .com...
  • Page 2: Table Of Contents

    Clearing memory contents ....................21 According to the conformity certificate, the instruments fulfill 2014/30/EC guidelines. © 1999 Copyright Testo GmbH & Co. The software and software structure included in the product testo 445/645 are protected by copyright laws worldwide. Testo-Direct info@Testo-Direct.com 1.888.610.7664 www.
  • Page 3: Foreword

    Foreword Dear Customer You have made the right decision by choosing a measuring instrument from Testo. Every year, thousands of customers purchase our high-quality products. There are many good reasons for this. 1) We offer value for money. Reliable quality at the right price.
  • Page 4: Initial Operation

    Open the battery compartment at the back of the instrument. Put in block battery. Observe polarisation. Close battery compartment. Refer to “Power supply” Chapter for more information on alternative power supply, charge, battery quality, charging procedure. Observe instrument configuration when using rechargeable batteries. Testo-Direct info@Testo-Direct.com 1.888.610.7664 www. .com...
  • Page 5: First Measurement

    Some things can only be set via PC software (See Ordering data):  Location name (8 characters)   Log head (24 characters), e.g. your company name - is also printed when readings are printed. Testo-Direct info@Testo-Direct.com 1.888.610.7664 www. .com...
  • Page 6: Instrument Description

    (NTC) and velocity location (ball) RS232: PC connection Arrow buttons 12V: Mains connection move the cursor testo 645 Hold Max Min Socket 1: Mean – Temperature probes (T/C type K/J/S or NTC) Socket 2: – Combined probe for humidity...
  • Page 7: Display

    Shows capacity of battery and rechargeable battery. If the inner segment no longer appears (symbol flashes), the battery has to be changed or the rechargeable battery has to be recharged. The instrument switches itself off automatically after 1 minute. Testo-Direct info@Testo-Direct.com 1.888.610.7664 www. .com...
  • Page 8: Overview Of Controls

    Start and end Calculate mean Reset mean Parameter settings Selected The setting functions are activated in accordance with the reading testo testo parameter selected - flashing cursor in display (See 1.): °C System adjustment with EEPROM probe (4.1) Reset - system adjustment Humidity probe (0636.9740 and 0636.9715)/...
  • Page 9 Print parameters AUTO Unit selection Program automatic saving • Select meas. °C°F cycles • Set m/sfpm [ft/min] (testo 445) measurement rate /min cfm [ft /min](testo 445) mbar Read memory in W [”H O] (testo 445) contents on display with...
  • Page 10: Current Measurement

    A distance 0f 0.5 m should not be exceeded in order to depending on probe(s) guarantee problem-free data transfer. Objects between connected. instrument and printer prevent the data from being transferred. Please observe notes in the instruction manual on the printer. Testo-Direct info@Testo-Direct.com 1.888.610.7664 www. .com...
  • Page 11: Measurement Functions 11-13 Freezing Readings

    34. 8 0 Hold Max/Min Mean Minimum readings since the M.05 N.0017 measurement began 1MIN Save measured 56. 6 2 value Print measured value 1MIN 20. 0 0 Hold Max/Min Mean See multi-point/timed mean calculation Testo-Direct info@Testo-Direct.com 1.888.610.7664 www. .com...
  • Page 12: Multi-Point Mean Calculation

    MEAN page 13) • Select parameter required. New mean calculation possible Update values. Calculate mean M.05 N.0017 MEAN 25. 2 1 Mean ME AN NE W Number of updated values • Save mean Print mean Testo-Direct info@Testo-Direct.com 1.888.610.7664 www. .com...
  • Page 13: Timed Mean Calculation

    55. 2 0 calculate mean. MEAN 00: 1 5  New mean calculation possible Mean M.05 N.0017 Timed duration of MEAN mean calculation 55. 2 1 MEAN NEW 00: 0 5 Save mean. Location  Print mean. Testo-Direct info@Testo-Direct.com 1.888.610.7664 www. .com...
  • Page 14: Location Selection

    The cross-section Use ESC to go Location can only be called up if to selection of volume flow is activated cross-section entry (testo 445 instrument) Ø AxB, m2, Funnel) Increase value 50. 0 Decrease value Select digit box Return to current...
  • Page 15: Parameter Settings

    - flashing cursor in display. M.05 N.0017 System adjustment (only possible in testo 645): testo 645 and probes with EEPROM (Part no. 0614.xxxx) can °C be adjusted to the “zero error adjustment point”. The probe 69. 6 characteristic saved in the measuring instrument is offset at a measurement point.
  • Page 16: Adjusting Humidity Probes

    N.0017 Displaying calculated humidity parameters. If Testo`s combination humidity probe (e.g. 0636.9740) is td°C connected, testo 445 and testo 645 display a calculated humidity parameter in addition to temperature and relative humidity. You 12.9 can select from the following parameters: td°C...
  • Page 17: Initialising Differential Pressure Probe (Testo 445)

    Initializing pressure probe / Activating velocity and volume flow The setting functions are activated in accordance with reading line selected - flashing cursor in display. M.05 N.0017 Differential pressure probe (testo 445 only): /h, in addition to mbar; Activating/deactivating m/s, m mbar initialisation 22.
  • Page 18: Memory Settings

    The symbol corresponding to the selection appears in the top line. 21. 8 0 The function is activated with Location Parameter settings (See Chapter 4). AUTO CLEAR CLEAR AUTO AUTO OU T MEMORY MEMORY MEMORY MEMORY Location Testo-Direct info@Testo-Direct.com 1.888.610.7664 www. .com...
  • Page 19: Manual Saving

    01: 3 series is accepted. M.05 N.0017 AUTO Cancel saving procedure. Location M.06 N.0001 m3/h Starts automatic saving again. An additional measurement series is 19665 AUTO added. Testo-Direct info@Testo-Direct.com 1.888.610.7664 www. .com...
  • Page 20: Reading Or Printing Memory Contents

    The N.0x counter flashes in the display. Location Select the measurement cycle by pressing activates a printout of the selected measurement cycle. M.05 N.0017 °C 79. 7 button enables you to go back one step. Location Testo-Direct info@Testo-Direct.com 1.888.610.7664 www. .com...
  • Page 21: Clearing Memory Contents

    21.2 44.7 22.3 M.001 Readings 21.1 44.6 22.3 31.08.1998 21.8 44.6 22.3 11:20:05 2:m/s 2:td°C 21.4 °C 1.00 2: 44.7 1.66 2: 22.1 °C 2.01 2: 0.55 1.52 2: 9.6 td°C Info : Info : Testo-Direct info@Testo-Direct.com 1.888.610.7664 www. .com...
  • Page 22: Instrument Configuration

    If the mains unit is connected and the charging procedure is confirmed:  Risk of explosion!!!! - Battery operation is set and rechargeable battery is put in: Rechargeable battery will not be charged. See page 24 Testo-Direct info@Testo-Direct.com 1.888.610.7664 www. .com...
  • Page 23: Setting Power Supply, With Rechargeable Battery Or Battery

    Correct battery recharging in the instrument via the mains unit can only be guaranteed if the above mentioned Testo rechargeable batteries are used. If other rechargeable battery types are used, recharging will have to be carried out by an external recharger.
  • Page 24: Setting Date/Time

    The flashing position in the display can be set 1998 = scroll/ = next position - Setting the time TIME 11: 2 5 The blinking position in the display can be set = scroll/ = next position - Testo-Direct info@Testo-Direct.com 1.888.610.7664 www. .com...
  • Page 25: Setting Parameters For Absolute Pressure And Density Compensation

    5. Pitot tube factor (testo 445) Pitot tube factor setting: The factor for Pitot tubes from Testo is constantly at 1.00 and Parameter does not need to be changed. If the Pitot tubes from other firms are used, ask your supplier for the Pitot tube factor and save in instrument.
  • Page 26: Unit Selection

    (m3/min) m3/s cfm (ft3/min) (testo 445 only) The selected parameter flashes.  Select  confirms the selection. Factory reset in W (”H2O) (testo 445 only) mbar The selected parameter flashes  Select  confirms the selection. M.05 N.0017 Factory reset °C...
  • Page 27: Velocity Measurement

    7. Velocity measurement Volume flow funnel (testo 445) A volume flow funnel is needed to measure the volume flow in a ventilation opening (grid or outlet with dual wall clearance). The opening of the funnel must be covered completely by the grid (max.
  • Page 28: Pitot Tube And Pressure Probe (Testo 445)

    The Pitot tube factor for testo Pitot tubes is at a constant 1.00 and does not need to be changed. If non-Testo Pitot tubes are used, please ask your supplier for the factor and save it.
  • Page 29 CO/CO2 measurement (testo 445) CO measurement (testo 445) The connected probe 0632.1247 is initialised during the switch- on phase (“Count Down” runs in the display). For this reason, the measuring instrument should only be switched on in an atmosphere free of CO. Values will be too low otherwise in subsequent measurements.
  • Page 30: Co/Co Measurement

    (testo 445) The 0632.1240 probe measures concentrations from 0 to 1 vol % CO 2 . The unit can be switched between ppm and vol% as described in “Parameter settings” on page 16. The measuring principle is based on infrared absorption. The probe has a relatively high power consumption on account of its sensor.
  • Page 31: Measuring Absolute Pressure

    Elevation Air pressure Air pressure Air pressure Air pressure Elevation Elevation Elevation M.S.L (mbar) (mbar) (mbar) (mbar) M.S.L M.S.L M.S.L Table: Barometric elevation formula Testo-Direct info@Testo-Direct.com 1.888.610.7664 www. .com...
  • Page 32 We therefore assume an absolute air pressure in the measurement medium of 1000 mbar. The table on page 31 is also saved in the Testo Comfort software. Absolute pressure can be calculated automatically using this software if the height above mean sea level, barometric pressure and differential pressure are entered.
  • Page 33: Error Messages

    Turn instrument on and off again If the error message returns, please contact your nearest Testo service point. Testo-Direct info@Testo-Direct.com 1.888.610.7664 www. .com...
  • Page 34: Technical Data

    Technical data - Instruments testo 645/445 testo 645/445 Type J (FeCu-Ni) General technical data Measuring range: -200 to +1000 °C Memory space: Up to 3000 readings ±0.3 °C or ±0.5 % of Accuracy* Power supply: Battery / rechargeable batt. reading at 22 °C:...
  • Page 35 Technical data - Instruments testo 645/445 testo 645 Pressure units can be switched: Temperature measurement mbar, psi; in W(”H Pt100 Calculated velocity values -200 to +800 °C measuring range: density compensated: 0 to 100 m/s Accuracy* ±0.2 °C or ±0.1 % of Calculated volume flow values: at 22 °C:...
  • Page 36: Ordering Data

    System case, aluminium for instrument, probes and additional accessories. Clear layout of case contents by placing 0516 0410 probes in lid. Additional accessories 9 V rechargeable battery for testo 445, testo 645 measuring instruments 0515 0025 PT 100-probes Meas. range / Accuracy Connection cable Part no..
  • Page 37 Ordering data Fühler für testo 645 / 445 NiCr-Ni probes Meas. range / Accuracy Connection Part no. sec. Quick-action surface probe with sprung thermocouple strip -200...+300°C, Short- Plug-in head 0604 0194 term up to +500 °C, Please order connection cable 0430.0143)
  • Page 38 Ordering data Probes for testo 645 / 445 Humidity/temperature Measuring range System Connection Part no. probes accuracy* sec. cable Standard indoor air quality probe up to +70 °C 0 to 100 %RH, probe ±2 %rH (2 to 98 %rH) <12...
  • Page 39 Ordering data Probes for testo 645 / 445 Accessories for humidity/temperature probes, 3-function probe Diameter Part no. Caps for all humidity probes Metal protection cage, material: stainless steel V4A. Quick adjustment time, robust and tempera- 21 mm 0554 0665 12 mm 0554 0755 ture-proof.
  • Page 40 Ordering data Probes for testo 645 / 445 Velocity probes Sensor Meas. range Accuracy (System) Part no.. Vane/temperature probe, can be attached to 0,6 to 60 m/s ±(0,2 m/s +1 % of m.v.) 0635 9540 handle or telescope -30 to +140 °C...
  • Page 41 Ordering data Probes for testo 645 / 445 Additional probes Sensor Meas. range Accuracy Part no. 3-function probe for simultaneous measurement Hot bulb 0 to 10 m/s ±(0,03 m/s +5 % v.Mw.) 0635 1540 of Ttemperature, humidity and velocity. With plug-...

This manual is also suitable for:

445