UTP 10/100Mbps "10/100" DIP-Switch (Port 1 or Port 2)
When the UTP "AN/MAN" DIP-Switch (described above) is in the manual
"MAN" position, the "10/100" DIP-Switch determines the speed of operation
for the designated UTP port. Setting the "10/100" DIP-Switch to "100"
position (factory default) forces the UTP port to operate at 100Mbps.
Setting this DIP-Switch to "10" position forces the UTP port to operate at
10Mbps. Adjust the "10/100" DIP-Switch to match the speed of the
connecting UTP device.
UTP Full/Half-Duplex "HD/FD" DIP-Switch (Port 1 or Port 2)
When the UTP "AN/MAN" DIP-Switch (described above) is in the manual
"MAN" position, the "HD/FD" DIP-Switch determines the duplex operation
mode for the UTP port. Setting the "HD/FD" DIP-Switch to UTP Full-Duplex
"FD" (factory default) position forces the UTP port to operate in Full-Duplex.
Setting this DIP-Switch to "HD" forces the UTP port to operate in
Half-Duplex. Adjust the UTP Half/Full-Duplex DIP-Switch to match
duplex mode the connecting UTP device.
When the UTP "AN/MAN" DIP-Switch is in the Auto-Negotiate "AN" position
and the UTP Full/Half Duplex DIP-Switch is in the Full-Duplex "FD" position,
the UTP port Auto-Negotiates to Full or Half-Duplex. When in the Half-Duplex
"HDX" position, the UTP port functions only in Half-Duplex.
3.3.2

Media Converter Module - Front Panel

The Media Converter Modules have been pre-configured as illustrated below.
Using the front panel DIP-Switches, the module can be reconfigured for
customer-specific applications.
Media Converter Module Front Panel DIP-Switches
Fiber Full/Half-Duplex "FDX / HDX" DIP-Switch
When in the Fiber Full/Half-Duplex DIP-Switch is in the "FDX" position
(factory default), the fiber port operates in Full-Duplex mode. When in the
"HDX" position, the fiber port operates in Half-Duplex mode and its distance
is limited by the IEEE 802.3 standard to 412 meters.
UTP Auto/Manual Negotiate "AN / MAN" DIP-Switch
When the UTP "AN/Man" DIP-Switch is in the Auto-Negotiate "AN"
position (factory default), the converter Auto-Negotiates and matches the