Wire Control Operation - Tebas BP-100HS-A Installation And Maintenance Manual

Swimming pool heat pump
Table of Contents

Advertisement

The function of the LED display and control:
Set the operation parameter:
When the unit powered up but not running, press "
interface. (parameter from 0-F, see Operation Parameter Table).
◎ Press "SET" to enter current parameter setting, press "
parameter, press "SET" again exit the current parameter setting.
◎ No press in 8s, it will exit the setting interface.
If the heat pump is running, press "
interface, But can't change parameters
setting in different modes).
◎ If the heat pump is running, the LED display shows current water temperature;
If the heat pump is turnoff, the LED display shows current time.
NO
Meaning
0
Cooling setting water temperature
1
Heating setting water temperature
2
Auto mode setting water temperature
Turnround of defrosting Under heat
3
mode
4
Defrosting start temperature
5
Defrost exit temperature
6
Time of exit defrost Under heat mode
7
Low ambient temperature protection
Compressor protection
8
Exhaust temperature
9
Automatic restart
A
Mode (heat/coo & heat)
b
Water pump mode
Water temperature difference to
C
restart
d
Water temperature
E
Compressor Exhaust temperature
F
Copper temperature
H
Ambient temperature

Wire control operation

" or "
(Except the parameter 0, 1, 2 for water temperature
15~45°C
15~45°C
15~45°C
30 ~ 90 min
-30 ~ 0°C
2 ~ 30°C
0 ~ 12 min
-20~10°C
95 ~ 110°C
0/1
0/1
0/1
-9 ~ 99°C
-9 ~ 125°C
-9 ~ 99°C
-9 ~ 99°C
7
" or "
" to enter operation parameter
" or "
" to enter operation parameter check
Range
Change
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
NO
YES
YES
1 ~ 10°C
Measured value
Measured value
Measured value
Measured value
"to set data for
Factory setting
27
27
27
40 (40 min)
-5°C
15°C
6 min
-7°C
95°C
1
1
1
2

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Tebas BP-100HS-A