9 – Error codes and what to do:
This table explains the error codes caused by a defective
regulating component or by a security operation.
Screen and state
of the heat pump
PP 01
Water temperature
Compressor and fan
sensor
stopped
compressor
PP 02
Compressor and fan
stopped
PP 03
The heat pump
Defrost sensor
continues running
PP 05
Ambient air
The heat pump
temperature
continues running
sensor
First anti-frost
PP 07
protection active
PP 07
Second anti-frost
protection active
EE 01
High pressure,
Compressor and fan
Low pressure
stopped
protection
EE 02
Low pressure
Compressor and fan
protection
stopped
EE 03
Compressor and fan
Flow switch
stopped
EE 04
The unit cannot be
Emergency switch
started
Low ambient
temperature
EE 05
Compressor and fan
protection
stopped
compressor
EE 06
Compressor and fan
stopped
EE 07
The unit cannot be
Phase protection
started
EE 08
Wire control
The wire control
Communication
can't operated
error
Component
Sensor disconnected,
non supplied or
defective
Sensor disconnected,
exhust
non supplied or
temperature
defective
sensor
The defrosting is
incomplete and the
automatism decides
to stop the heat pump
Sensor disconnected,
non supplied or
defective
Low temperatures for
water and air
Low temperatures for
water and air
Insufficient water
flow
Pressure switch out
of order
Too much refrigerant
gas present
Not enough
refrigerant gas
Leak in the cooling
conduits
Flow switch
disconnected, non
supplied or defective
Emergency switch
disconnected
Ambient temperature
is too low or
protection
temperature setting
set too low
Compressor exhaust
temperature
exhaust
detected up to 95°C
temperature
more than 3 times in
sensor
1HR
Connection
disconnected or
wrong phase wiring
Signal cable of wire
Control is loose
Possible
Intervention
Check the connections, the wires,
change it or replace the electronic card
Check the connections, the wires,
change it or replace the electronic card
Increase lightly the water flow going into
the heat pump; the effect is to increase
the temperature of the refrigerant in the
evaporator.
Check the connections, the wires,
change it or replace the electronic card
No action required
No action required
Check the water flow
Replace the pressure switch Have
the heat pump checked by a
refrigeration technician
Have the heat pump checked by a
refrigeration technician
Have the heat pump checked by a
refrigeration technician
Check the connections, the wires,
change it or replace the electronic card
Check the connections and the wires
Check and repair.
Environment problem
Refrigerant leakage
Capillary is half blocked
Check the connections
Put phases in order
Check the connection of signal cable
16
20
Second reason if
the
intervention is
without effect