Download Print this page

Industrial Test Systems 486691 Instruction Manual

Ideal for drinking water, pools and spas, environmental, & educational testing

Advertisement

Quick Links

eXact
Strip Micro DPD-1 Accuracy
®
Free Chlorine results are compared using the eXact
Menu CL1 and Hach
®
DR890 Colorimeter in Program 9 and Program 12 using Hach
DR890
Micro 7+
0.00
0.01
0.04
0.03
0.07
0.08
0.79
0.73
0.98
0.96
1.55
1.52
2.08
2.12
2.4
2.6
2.9
3.3
4.0
3.9
5.5
5.2
Meter
Menu
Range (PPM)
Resolution
0.00 to 2.39
0.01
Micro 7+ CL1
2.4 to 6.0
0.1
DR890
0.00 to 2.20
0.01
Program 9
0.0 to 11.0
0.1
Program 12
Hach
®
is a registered trademark of Danaher Corporation
The eXact
Micro 7+ Line of Kits
®
(486691-K)
(486691-KP)

Standard Kit

Pool/Spa Kit
Includes:
Includes:
®
(486691)
1 eXact
Micro 7+ Meter
1 eXact
eXact
®
Strip Micro DPD-1
(486637-25)
eXact
®
Strip Micro DPD-1
eXact
®
Strip Micro DPD-3
(486638-25)
eXact
®
Strip Micro DPD-3
eXact
®
Strip Micro pH
(486639-25)
eXact
®
Strip Micro pH
eXact
®
Strip Micro Total Alkalinity
eXact
®
Strip Micro Total Alkalinity
(486641-25)
(486641-25)
eXact
®
Strip Micro Calcium Hardness
eXact
®
Strip Micro Calcium Hardness
(486629-25)
(486629-25)
eXact
®
Strip Micro Copper
(486632-25)
eXact
®
Strip Micro Copper
1 Mixing Cap
eXact
®
Reagent Cyanuric Acid
1 Cell Cleaning Brush
1 Mixing Cap
This Instruction Booklet
1 Cell Cleaning Brush
Plastic Carrying Case
This Instruction Booklet
AAA Batteries (4)
Plastic Carrying Case
AAA Batteries (4)

Contact Information

For US Inquiries and Re-Orders:
Industrial Test Systems, Inc.
1875 Langston Street,
Rock Hill, SC 29730 USA
Phone: 1-800-861-9712 - INSIDE THE U.S.
1-803-329-9712 - OUTSIDE THE U.S.
Fax: 1-803-329-9743
ITS@SENSAFE.COM
WWW.SENSAFE.COM
www.poolcheckonline.com
®
Strip Micro CL (DPD-1) with the eXact
®
®
powder pillows.
eXact Strip DPD-1 on Hach DR890 and eXact Micro 7
6.00
5.00
y = 0.9703x + 0.0561
2
R
= 0.9912
4.00
3.00
2.00
1.00
0.00
0.00
1.00
2.00
3.00
4.00
ppm (mg/L)
Hach DR890 (ppm)
(486691-WD)
Well Driller Kit
Includes:
®
(486691)
®
Micro 7+ Meter
1 eXact
Micro 7+ Meter
(486637-25)
eXact
®
Strip Micro DPD-1
(486638-25)
eXact
®
Strip Micro DPD-3
(486639-25)
eXact
®
Strip Micro pH
eXact
®
Strip Micro Total Alkalinity
(486641-25)
eXact
®
Strip Micro Calcium Hardness
(486629-25)
(486632-25)
eXact
®
Strip Micro Copper
(481652)
eXact
®
Reagent Iron
eXact
®
Micro Manganese
1 Mixing Cap
1 Cell Cleaning Brush
This Instruction Booklet
Plastic Carrying Case
AAA Batteries (4)
For European & Middle East Inquiries and Re-Orders:
ITS Europe, LTD
Unit B Stanley Crt., Glenmore Business Park, Telford Rd.
Churchfields Industrial Estate,
Salisbury, Wiltshire SP2 7GL, United Kingdom
Tel: +44 (0)1722 329502 Fax: +44 (0) 1722 329880
SALES@SENSAFE.COM
WWW.ITSEUROPE.CO.UK
www.poolcheckonline.com
32
Micro 7+ Meter in
+
IDEAL FOR DRINKING WATER, POOLS AND SPAS,
ENVIRONMENTAL, & EDUCATIONAL TESTING
USEPA, DIN, & ISO Compliant for Free & Total Chlorine Testing
(4500-CL G, DIN Standard 38 408 G4, ISO 7393/2)
U.S. Patent No. 7,333,194, U.S. Patent No. 7,491,546, South African Patent No. 2007/0628 and international
patent applications including International Patent Appln. No. PCT/US2005/033985; and Eur. Pat. App. 1,725,864
5.00
6.00
(486691)
(486637-25)
(486638-25)
(486639-25)
(486632-25)
(481623)
(486606)
The eXact
Micro 7+ Ad
Micro 7+ Advanced
®
Photometer System has been
designed for use with the eXact
Micro reagent delivery system.
Manufactured By: Industrial Test Systems, Inc.
1875 Langston Street, Rock Hill, SC 29730 USA
Phone: 1-800-861-9712 - INSIDE THE U.S.
1-803-329-9712 - OUTSIDE THE U.S.
© 2009 Industrial Test Systems, Inc. • EXACT
Micro 7+
Advanced Photometer System
19
uding Inter
Index:
P
Parameter
Free Chlorine (DPD-1)
F
Permanganate (DPD-1)
Total Chlorine (DPD-3)
Ozone (DPD-4)
Total Chlorine (DPD-4)
pH
Bromine
Total Alkalinity
Calcium Hardness (as CaCO
Copper
(NOTE: The below tests are read as %Transmission and
require use of a conversion table)
General TR7 Procedure
Turbidity
Cyanuric Acid
Ammonia
Chloride (in Tap Water)
Iron (as Fe
LR Total Hardness (up to 77ppm)
Nitrate
Nitrite
Manganese
Fluoride
Chloride (Pool Salt Systems)
Chlorine Dioxide (DPD-1)
Iron (as Fe
Alkali pH
m ha
Acid pH
Strip
®
Chromate (Chromium)
Sulfate (SO
Specifications
About Your Photometer
Notes
Tips for Best Accuracy
Battery Installation
Warranty (2 year)
Fax: 1-803-329-9743
ITS@SENSAFE.COM
Reorder Information
USEPA Compliance
WWW.SENSAFE.COM
Kit Components
www.poolcheckonline.com
Visit us online at sensafe.com/micro7+ for up-to-date
product information & NEW tests available.
®
is a registered trademark of Industrial Test Systems, Inc., Rock Hill, SC USA
Revision 03/05/09
486691-K Standard Kit
486691-KP Pool/Spa Kit
486691-WD Well Driller Kit
Page
MENU
4
CL1
4
CL1
5
CL1
6
CL1
6
CL1
6
PH2
7
BR3
7
AL4
)
8
CA5
3
8
CU6
9
Tr7
10
Tr7
11
Tr7
12
Tr7
13
Tr7
+2
/ Fe
+3
)
14
Tr7
15
Tr7
16
Tr7
17
Tr7
18
Tr7
19
Tr7
20
Tr7
21
Tr7
+2
)
22
Tr7
23
Tr7
24
Tr7
25
Tr7
)
26
Tr7
4
2
3
27-28
29
30
30
31
2, 32
32

Advertisement

loading

Summary of Contents for Industrial Test Systems 486691

  • Page 1: Standard Kit

    Kit Components WWW.SENSAFE.COM www.poolcheckonline.com www.poolcheckonline.com Visit us online at sensafe.com/micro7+ for up-to-date www.poolcheckonline.com product information & NEW tests available. © 2009 Industrial Test Systems, Inc. • EXACT ® is a registered trademark of Industrial Test Systems, Inc., Rock Hill, SC USA...
  • Page 2 eXact Micro 7+ Photometer eXact Strip Micro 7+ Reagent Reorder Information ® ® ITEM PICTURED COMPONENT LETTER NAME Mixing Cap Cell (Built-in Plastic, 4 ml) LCD Display READ Button MENU Button ZERO/ON Button Battery Cover with loop for lanyard AAA Batteries (x4) (Used for Cyanuric Acid, Fluoride, Iron, and Manganese tests)
  • Page 3: Top View

    eXact Micro 7+ Meter Messages About Your eXact Micro 7+ Instrument ® ® The following are some common messages that may be displayed, including error messages. If an In order to save power, the meter is designed to turn off after 3 minutes (timed from the last button pressed). error message other than those listed below is displayed, please contact technical support in the USA Should the meter turn off in the middle of a test, the last stored zero in the meter will remain valid when the at (803) 329-0162 (ext.
  • Page 4: Remove Strip

    DPD-1 Free Chlorine Test Procedure eXact Micro 7+ Tips For Best Accuracy ® Become familiar with the meter and the different tests by reading the instructions carefully. REMOVE STRIP The DPD-1 & DPD-4 strips supply enough reagent for accurate results at room temperature. If Remove one (1) eXact ®...
  • Page 5 NOTES DPD-3 Total Chlorine Test Procedure This procedure is only valid when run as a continuation of the ® eXact Strip Micro CL (DPD-1 Free Chlorine ) Test Procedure located on the previous page. REMOVE STRIP Remove one (1) eXact ®...
  • Page 6 NOTES DPD-4 Test Procedure (Total Chlorine or Ozone) REMOVE STRIP ® Remove one (1) eXact Strip Micro CL (DPD-4 for Total Chlorine or Ozone), part number 486670, from the bottle before beginning the test. Set the strip in a dry, convenient place and recap the bottle immediately.
  • Page 7 Sulfate (SO ) Test Procedure DPD-1 Bromine Test Procedure REMOVE STRIP TURN METER ON ® Press the ZERO/ON button to power the meter on; the display will show all annunciators, then Remove one (1) eXact Strip Micro CL (DPD-1), part number 486637, from the bottle before beginning the test.
  • Page 8 Calcium Hardness Test Procedure Chromate (Chromium) Test Procedure REMOVE STRIP TURN METER ON ® Remove one (1) eXact Strip Micro CA, part number 486629, from the bottle before Press the ZERO/ON button to power the meter on; the display will show all annunciators, then beginning the test.
  • Page 9 Acid pH Test Procedure Transmission Test Procedure ACID ph TURN METER ON REMOVE STRIP Press the ZERO/ON button to power the meter on; the display will show all annunciators, then Remove one (1) eXact ® Strip Micro, part number is dependent upon the test being run, the current MENU selection, followed by the last reading.
  • Page 10 Alkali pH Test Procedure Turbidity Test Procedure Alkali ph TURN METER ON TURN METER ON Press the ZERO/ON button to power the meter on; the display will show all annunciators, then Press the ZERO/ON button to power the meter on; the display will show all annunciators, then the current MENU selection, followed by the last reading.
  • Page 11 Iron Test Procedure Cyanuric Acid Test Procedure (as Fe TURN METER ON TURN METER ON Press the ZERO/ON button to power the meter on; the display will show all annunciators, Press the ZERO/ON button to power the meter on; the display will show all annunciators, then the current MENU selection, followed by the last reading.
  • Page 12 Chlorine Dioxide Test Procedure Ammonia (NH ) Test Procedure TURN METER ON TURN METER ON Press the ZERO/ON button to power the meter on; the display will show all annunciators, then Press the ZERO/ON button to power the meter on; the display will show all annunciators, the current MENU selection, followed by the last reading.
  • Page 13 For Pool and Spa Salt Systems For Tap Water Chloride (as NaCl) Test Procedure Chloride (as NaCl) Test Procedure CHLORIDE CHLORIDE TURN METER ON TURN METER ON Press the ZERO/ON button to power the meter on; the display will show all annunciators, Press the ZERO/ON button to power the meter on;...
  • Page 14 Iron (Fe ) Test Procedure Fluoride Test Procedure — (SPADNS) TURN METER ON NOTE: Water samples with suspended solids and particulates may cause incorrect results, since the reducing agent in the Press the ZERO/ON button to power the meter on; the display will show all annunciators, then powder pillow often dissolves the suspended solids and particulates.
  • Page 15 Manganese Test Procedure LR Total Hardness Test Procedure (as CaCO TURN METER ON TURN METER ON Press the ZERO/ON button to power the meter on; the display will show all annunciators, Press the ZERO/ON button to power the meter on; the display will show all annunciators, then then the current MENU selection, followed by the last reading.
  • Page 16 Nitrate (NO ) Test Procedure Nitrite (NO ) Test Procedure TURN METER ON TURN METER ON Press the ZERO/ON button to power the meter on; the display will show all annunciators, Press the ZERO/ON button to power the meter on; the display will show all annunciators, then then the current MENU selection, followed by the last reading.

This manual is also suitable for:

Exact micro 7+