The recommended hose size is .500 inch/12 mm I.D. up
to 50 ft/15 m long and .625 inch/16 mm I.D. minimum up
to 100 ft/30 m.
PRE-OPERATION PROCEDURES
CHECK POWER SOURCE
1. Using a calibrated flowmeter and pressure gauge,
check that the hydraulic power source develops a
flow of 7–9 GPM/26–34 LPM at 1500–2000 psi/105–
140 bar or 5–6 GPM /18–22 LPM at 1500–2000 psi
/105–140 bar.
2. Make certain the hydraulic power source is equipped
with a relief valve set to open at 2250 psi/155 bar
maximum.
INSTALL TOOL BIT
1. Rotate the latch on the breaker foot downward
(pointing away from the tool).
2. Insert the tool bit into the foot and pull the latch up to
lock the tool bit in place.
CONNECT HOSES
1. Wipe all hose couplers with a clean, lint-free cloth
before making connections.
2. Connect the hoses from the hydraulic power source
to the tool fittings or quick disconnects. It is a good
practice to connect return hoses first and disconnect
them last to minimize or avoid trapped pressure
within the tool.
3. Observe flow indicators stamped on hose couplers
to ensure that fluid flow is in the proper direction. The
female coupler on the tool hose is the inlet coupler.
4. Move the hydraulic circuit control valve to the ON
position to operate the tool.
NOTE:
If uncoupled hoses are left in the sun, pressure
increase within the hoses may make them difficult
to connect. When possible, connect the free ends of
the hoses together.
OPERATION PROCEDURES
1. Observe all safety precautions.
2. Install the appropriate tool bit for the job.
3. Place the bit firmly on the surface to be broken.
4. Squeeze the trigger to start the breaker. Adequate
down pressure is very important. When the tool bit
breaks through the obstruction or becomes bound,
release the trigger and reposition the tool bit.
10 ► BR45 User Manual

OPERATION

NOTE:
Partially depressing the trigger allows the tool to run
at slow speed. Slow-speed operation permits easier
starting of the tool bit into the work surface.
5. To start, break an opening (hole) in the center of
the surface. After making a hole, break portions
of the material into the original opening. For best
productivity, the breaking should be done around
the original hole.
The size of the broken material will vary with the
strength and thickness of the base material and the
amount of any reinforcement wire or rebar.
Harder material or more reinforcing wire or rebar will
require taking smaller bites. To determine the most
effective bite, start with 2 in. / 50 mm or smaller bites.
Bites can then be gradually increased until the
broken piece becomes too large, requiring increased
time to break off the piece.
Sticking of the tool bit occurs when too large a bite
is being taken and the tool bit hammers into the
material without the material fracturing. This causes
the tool bit to become trapped in the surrounding
material.
COLD WEATHER OPERATION
If the breaker is to be used during cold weather, preheat
the hydraulic fluid at low engine speed. When using the
normally recommended fluid, fluid temperature should
be at or above 50 °F/10 °C (400 ssu/82 centistokes)
before use.
Damage to the hydraulic system or breaker can result
from use with fluid that is too viscous or thick.

Advertisement

Table of Contents
loading

Table of Contents