• ...the device is stored and operated according to LogTag Recorders’ recommendations. Disclaimer The USRIC-8 monitors temperature exposure and not the quality of the goods it accompanies. Its purpose is to signal if product quality evaluation/testing is required. Typographical conventions...
Can be used to stop the unit. 1 Depending on the configuration, the USRIC-8 may produce any of the supported file types *.ltd, *.csv or *.pdf, or none at all if file generation is disabled when configuring the unit.
You cannot combine a date/time start with pre-start readings or the start delay function. If you configure the USRIC-8 for a time start, but you leave it plugged into the USB port until after the configured time has passed, the unit will start as soon as it is unplugged.
Unplugging Plugging the USRIC-8 into a USB port You can unplug a USRIC-8 at any time; there is no need to stop the device via the shortcut menu in the notification area on the taskbar. What happens when you plug the USRIC-8 into a USB port...
LED every second Ready for re-flash The red LED is on • A permanently lit red LED light indicates the USRIC-8 is ready to receive new firmware. permanently Special software is required to upload new firmware to the USRIC-8.
Here you can see the settings that were uploaded during the configuration of the time it would otherwise have taken a reading. USRIC-8. It shows how the recorder was started, if a start delay was active and the Alarm limits interval used for the readings.
Getting help File information The information from the report page is repeated here. If after studying the ‘USRIC-8 Quick Start Guide’ you still need Data list further information, please visit the support section of the LogTag The Data list shows a single row for each recorded reading, along with the with date,...
USRIC-8 Factory Presets LogTag® USRIC-8 recorders can be client configured using LogTag Analyzer. For an out-of-box solution they can also be ordered in volume, pre-configured with a factory profile ready for starting. If a default configuration does not suit, customers can compile their own profile by specifying the parameters in the table below when ordering.
Power source CR2032 3V non-rechargeable, non-replaceable Lithium battery– Battery life Shelf life of up to two years before configuration. Six months operating life from the time of configuration. LogTag® is a registered trademark of LogTag Recorders Ltd. Page 11 of 11...
Need help?
Do you have a question about the USRIC-8 and is the answer not in the manual?
Questions and answers