12. IKI‐Kiuas Ltd. recommends the use of safety railings around the heater. However, the 
stainless steel frame does not over‐heat the way ordinary steel‐cased heaters do. 
 
13. The surface of the stones sinks in a little after the heater has been in use for a while. 
Frequently check that the heating elements do not become exposed. If this should 
happen, pile in more stones. The disintegration of the stones depends on the type of 
stones and the frequency of use. The condition of the stones should be checked yearly 
and broken stones should be replaced by new ones. 
 
 
Connecting the electric heater to electrical network 
 
 
The heater is connected to the electrical network semi‐stationarily with a H07RN‐F rubber cable or 
its equivalent. The use of PVC‐insulated cable as a connecting cable is prohibited due to thermal 
embrittlement. The electric installation may only be administered by a qualified electrician 
adhering to current regulations. The maximum distance of the junction box from the floor is 400 
mm, measured from the upper corner of the box.  Make sure that the connecting cable will not be 
exposed to thermal radiation or mechanical strain. If the rubber cable running inside the wall of 
the sauna is above 1000 mm from the floor, it needs to endure temperatures up to 170  
degrees Celsius (for example SSJ).  
 
 
Control unit 
 
The control cable for electrical heating is brought directly into the junction box of the heater, and 
from there to the terminal block of the heater.  The power and control unit should be installed in 
to a dry place between the heater and the electrical center, either in the sauna or outside the 
sauna (depending on the model). The thermostat is installed into the wall/or roof of the sauna 
according to instructions and is connected with SSJ or similar silicone cable to the power unit.  
See the more detailed instructions provided by  the control unit's manufacturer. 
 
 
Temperature restrictor (overheat protector) 
 
The temperature restrictor switches off the power if the temperature in the saunaroom climbs 
dangerously high. If the restrictor goes off, the cause is not a temporary malfunction. In this case 
consult the manufacturers technical support.  
See the more detailed instructions provided by the control  unit's manufacturer. 
 
 
 
 
 
 
 