IKI-Kiuas 6,9 Installation And User Manual

Monolith electric heater

Advertisement

Quick Links

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
10/2015

Advertisement

Table of Contents
loading

Summary of Contents for IKI-Kiuas 6,9

  • Page 1                                                       10/2015...
  • Page 2: Table Of Contents

        5  Instructions for bathing           5  Requirements for water quality         6  Trouble‐shooting           6  Circuit connector installation  6,9‐9 kW        7  Circuit connector installation 13,8‐18 kW with two circuits    8  Circuit connector installation 13,8‐18 kW with one circuit    9  Safety distances           10  Piling of the stones      ...
  • Page 3: Installation Instructions

    Installation instructions  ‐ Read through these instructions with care before you begin the installation process.   ‐ The electrical installation must be performed by a qualified electrician.  ‐ Separate instructions for electrical connections come with the control unit and/or the  circuit diagrams of these instructions.  ‐ Beware of sharp edges and use a long‐sleeved shirt and protective gloves during the  installation and while piling the stones.    1. Remove the protective plastic covering from the heater.    2. Choose the place for the heater according to the required safety distances.  The  minimum safety distances to inflammable surfaces for Monolith electric  heater,  measured from the heater's frame outwards, are 100 mm on the sides and the back of  the heater and 800 mm to the ceiling (Page 9).     3. Pay attention to the ventilation of the sauna room, the ideal placement for the  thermostat's sensor and the control unit. (PAGE 7‐8)    4. Lift the steel frame from the resistor casing/stand.    5. Open the element box located at the underneath the heater and connect  the five‐pole  electric cable through the socket seal to the terminal block  inside the box. (PAGE 6)    6. Attach the other end of the cable to the control unit and connect it according to the  specified instructions inside the control unit (controller).    7. Take the cable from the control unit (controller) either to the socket or electrical main  center.    8.
  • Page 4: Connecting The Electric Heater To Electrical Network

      12. IKI‐Kiuas Ltd. recommends the use of safety railings around the heater. However, the  stainless steel frame does not over‐heat the way ordinary steel‐cased heaters do.    13. The surface of the stones sinks in a little after the heater has been in use for a while.  Frequently check that the heating elements do not become exposed. If this should  happen, pile in more stones. The disintegration of the stones depends on the type of  stones and the frequency of use. The condition of the stones should be checked yearly  and broken stones should be replaced by new ones.      Connecting the electric heater to electrical network      The heater is connected to the electrical network semi‐stationarily with a H07RN‐F rubber cable or  its equivalent. The use of PVC‐insulated cable as a connecting cable is prohibited due to thermal  embrittlement. The electric installation may only be administered by a qualified electrician  adhering to current regulations. The maximum distance of the junction box from the floor is 400  mm, measured from the upper corner of the box.  Make sure that the connecting cable will not be  exposed to thermal radiation or mechanical strain. If the rubber cable running inside the wall of  the sauna is above 1000 mm from the floor, it needs to endure temperatures up to 170   degrees Celsius (for example SSJ).       Control unit    The control cable for electrical heating is brought directly into the junction box of the heater, and  from there to the terminal block of the heater.  The power and control unit should be installed in  to a dry place between the heater and the electrical center, either in the sauna or outside the  sauna (depending on the model). The thermostat is installed into the wall/or roof of the sauna  according to instructions and is connected with SSJ or similar silicone cable to the power unit.   See the more detailed instructions provided by  the control unit's manufacturer.      Temperature restrictor (overheat protector)    The temperature restrictor switches off the power if the temperature in the saunaroom climbs  dangerously high. If the restrictor goes off, the cause is not a temporary malfunction. In this case  consult the manufacturers technical support.  ...
  • Page 5: Using The Thermostat And Adjusting The Temperature

    Using the thermostat and adjusting the temperature    In various control unit models the selected bathing temperature is shown on the screen of the  control panel. The thermostat sensor must not be installed less than 1000 mm from an undirected  incoming air valve or less than 500 mm away from an incoming air valve which has been directed  away from the control unit.  See the more detailed instructions provided by the control unit's manufacturer.      Timer functions    Various control unit models have many various timer options. Attn. more than 4 hr operational  time is prohibited in private use and should be consulted by qualified electrician.  See the more detailed instructions provided by the control unit's manufacturer and local laws.      Instructions for bathing    Before bathing for the first time, heat up the heater once to burn off the protective oil solvents.  Note that you need to ventilate the sauna room efficiently  before you begin bathing.     The heating time for the stones and the sauna room is about 60 minutes  depending on the size of  the room and its ventilation. Throwing water on the heater increases temperature and humidity.  The top of the pillar creates more heat, while the sides create a gentler steam.    The temperature should be set by the temperature control in the control unit. A recommended  temperature for the bathing with this heater is 55–70 degrees.    Maintenance:    Due to large variation in temperature, the sauna stones disintegrate in use.  Pay attention  especially to the gradual settling of the stones. Be sure that the heating elements do not appear  with time. The stones settle most rapidly within two months of piling. Rearrange the stones at  least once a year or even more often if the sauna is in frequent use. At the same time, remove any  pieces of stones from the bottom of the heater and replace any disintegrated stones with new  ones. By also leaving free airflow and spacing between the saunastones, the heating capability of  the heater stays optimal, is faster and the risk of overheating is avoided.    NOTE! The maximum volume of the ladle is 0.5 litres. If an excessive amount of water is poured on  the stones, only part of it will evaporate and the rest may splash as boiling hot water on the  bathers. Never throw water on the stones  when there are people near the heater, because hot ...
  • Page 6: Requirements For Water Quality

    Requirements for water quality                       Water property  Effects      Recommendation  Humus concentration  Color, taste, precipitates  <12 mg/l  Iron concentration  Color, smell, taste, precipitates  <0,2 mg/l  Hardness: most important  Precipitates  Mn: <0,05 mg/l  substances are manganese  Ca: <100 mg/l  (Mn) and lime, i.e. calsium (Ca)  Chlorinated water  Risk to health  Use is completely forbidden  Seawater  Fast corrosion  Use is completely forbidden      Trouble shooting    If the heater or sauna room does not heat up, check that:    1. The power is on.    2. The power switch (start button on the control panel) is on.    3. The temperature knob is set to a higher temperature than the temperature in the sauna  room. ...
  • Page 7: Circuit Connector Installation  6,9-9 Kw

    Circuit connector diagram Monolith 6,9 and 9 kW                              7   ...
  • Page 8: Circuit Connector Installation 13,8-18 Kw With Two Circuits

    Circuit connector diagram Monolith 13,8, 15,9  and 18 kW with two circuits            8   ...
  • Page 9: Circuit Connector Installation 13,8-18 Kw With One Circuit

    Circuit connector diagram Monolith 13,8, 15,9  and 18 kW with one circuit                9   ...
  • Page 10: Safety Distances

    Safety distances from the heater Safety distances to flammable structures: Back Front Side Monolith 6,9 kW 100 mm 100 mm 100 mm 800 mm Monolith 9 kW 100 mm 100 mm 100 mm 800 mm Monolith 13,8 kW 100 mm...
  • Page 11: Piling Of The Stones

    Piling of the stones    Use protective gloves when piling the stones to the heater because there may be sharp edges in  the heater. If needed wash the stones before you pile them.     Max. amount of stones:  Monolith 6,9‐9 kW 120 kg  Monolith 13,8‐18 kW 220 kg    Piling the stones should be done with care. The stones should be placed so that the gap between  the heating elements and the frame of the heater is completely filled with stones for the whole  height of the heater. The stones should not be placed too tightly together; instead there should be  enough space between the stones to allow air to flow freely. Please make sure that elements  make NOT contact with each other or with the heater frame.    In private use, we recommend olivine, olivine‐dolerite and peridotite stones. The stones should be  smaller than 10 cm in diameter, so that they are easy to pile in between the heating elements and  the mesh frame. In ordinary use the stones should be changed every 2 to 5 years, depending on  how frequently the sauna is used.                      11   ...
  • Page 12: Warranty

        Warranty    IKI‐Kiuas Ltd. (the manufacturer) grants its products warranty according to the following  conditions. The manufacturer guarantees the quality and functionality of its products for the  duration of the warranty period The warranty applies to products sold and in use in EU region. The  warranty requires that the buyer of the product follows the manufacturer’s instructions regarding  the placement of the heater, its installation, use and maintenance as well as those regarding the  qualities of the stones used in the heater. The length of the warranty in private use is 24 months  from the day of purchase. The warranty period for spa saunas and other public use saunas is 6  months, or determined according to the frequency/level of use. Contact the manufacturers for  more details.    The warranty for electric heaters requires that:    1. In case of defect or malfunction, the buyer must always contacts the manufacturer or sales  agent first before searching for the cause or attempting to repair it.  2.  In private apartment use, the heater’s stone space needs to be re‐piled at least once a  year and weathered stones need to be replaced with new ones.  3. In institutional or professional use, the heater’s stones must be re‐piled at least three times  a year during the warranty period. In addition, the stones must be changed to new ones at  least once a year. Proof of the operation must be presented at request. The product’s  purchase receipt or build site’s acceptance certificate or similar report functions as the  warranty certificate. The use of ceramic heater stones (other than Kerkes ceramic heater  stones) is prohibited. In case of use of ceramic stones, the manufacturer’s warranty does  not apply.  4. The warranty does not cover dismantlement or reinstallation on sauna benches, removal of  sauna stones nor re‐piling them. IKI‐Kiuas Ltd. recommends using for the lower levels  sauna benches that can be moved without using tools to dismantle structures.   5. The warranty for replacement parts is 12 months from the day of purchase. The  replacement for a damaged part will be delivered to the reseller cost free. The use of an  authorized mechanic is required for installation of the replacement part. The manufacturer  is not liable to reimburse any costs occurred during the removal of the faulty part or the  installation of the replacement. The faulty part must be returned to the manufacturer at  request and at the expense of the owner. The manufacturer will issue its freight contacts ...
  • Page 13 7. Damage notifications: The owner is responsible for notifying the manufacturer, the sales  agent, or manufacturer’s authorized mechanic of any damage or malfunction as soon as it  appears and within 14 days. Any warranty related claims must be submitted within 14 days  from the closing date of the product’s warranty period.  8. Manufacturer’s actions regarding warranty, continuation of warranty: In receipt of a  substantiated warranty claim, the manufacturer will repair or change the product. This is  done in the manufacturer’s expense, and the manufacturer is free to select the most cost‐ effective alternative. The warranty for replacement parts is outlined above in section 5.  The replacement part is granted warranty according to specifications in section 5.The  warranty for a repaired part continues as before.   The manufacturer is not liable for reimbursing any expenses, business loss or other direct  or indirect harm occurred to the buyer from damages or malfunction.    Quality Guarantee    Guarantee of materials. The manufacturer guarantees the durability of the stainless steel parts  (resistor platform and frame) in private home use for 10 years. During the warranty period any  defects that appear in the heater's raw materials or are production‐ based will be repaired free of  charge. For example, the use of sea water on the heater is forbidden. Read through the  requirements for water quality in the installations instructions. The warranty does not cover color  changes, slipping or hair‐line fractures, characteristic to natural stones, which do not affect the use  or the safety of the heater.    Freight warranty    Damages occurred while shipping must to be recorded in the waybill when the product is received  or within 7 days of delivery. Shipping damage must also always be reported to the shipping  company’s last contact. The damaged part needs to be stored for inspection. Insurance  compensates for the new part, which will be delivered by a public transporter. In all issues  concerning warranty contact the store the product was bought from.                   ...
  • Page 14: Ventilation In The Sauna

      Mechanical ventilation in a sauna with an electric heater    Attention should be paid to the ventilation in the sauna room. Due to proper ventilation, the  sauna‐goers can enjoy clean and fresh, oxygen‐rich air. The air in the sauna should change six  times in one hour. The fresh air pipe should be located on top of the heater either in the wall or  the ceiling, at approximately 500 mm from the heater and the diameter of the pipe should be 50– 100 mm. The exhaust air pipe should be as far away from the heater as possible, yet close to the  floor. The exhaust air pipe should be twice the size of the supply air pipe.                            14   ...
  • Page 15: Warnings

    Warnings      1. Staying in the hot sauna for long periods makes the body temperature rise, which can be  dangerous.     2. Keep away from the heater when it ́ s  hot. The stones and outer surface of the heater may  burn.     3. Consult your doctor about any health‐related limitations to bathing.     4. Consult your child welfare clinic about taking little babies to the sauna.     5. Always move carefully in the sauna, as the platform and floors may be slippery.    6. Never go to a hot sauna if you have taken alcohol, strong medicines or narcotics.    7. Never sleep in a hot sauna.    8. Sea air and a humid climate may corrode the metal surfaces of the heater.    9. Do not hang clothes to dry in the sauna, as thismay cause a risk of fire. Excessive moisture  content may also cause damage to the electrical  equipment.    10. Keep children away from the heater.    11. Do not let young, handicapped or ill people bathe in the sauna by themselves.   ...
  • Page 16                                 16   ...

This manual is also suitable for:

15,913,8189