Where should Flood Detectors be Located? 
 
Flood detectors should be located on the floor below the bath, wash basin, or kitchen sink or anywhere a tap could be left 
running. It should be fixed to the skirting board with the screw or self adhesive pad provided. 
 
Tools Required 
 
A Pozi screwdriver will be needed if the flood detector is being screw‐fixed to the skirting board. 
 
Testing and Registering the Flood Detector 
 
Place a damp cloth across the 2 brass studs to activate.  
 
Depending on the moisture level of your skin, it may be 
possible to activate the device by placing your fingers 
across the 2 brass studs. 
 
The RED "Activated" light will flash for about 8 seconds 
when a flood alarm is being transmitted. 
 
The flood detector must be activated when registering 
onto the warden call, at‐home alarm or Nursecall system. 
 
See the following pages for how to put each of these  
products into registration mode.  
 
The range of all radio devices can be affected by the working environment ‐ always take care during installation and 
perform several test calls. 
 
Installation  
 
It is easier to test and learn the flood detector before fixing – see above. 
 
When fixing; always ensure the 2 brass studs are touching the floor. 
 
Select the best location, then fix to the skirting board with the single screw through  
the hole in the right angle bracket.   
 
If using the self adhesive pad; select a location where the skirting board is clean and dry. 
Stick the adhesive pad to the rear of right angle bracket then press the detector firmly  
to the skirting board ensuring it is stuck securely.  
 
Flood Alarms 
 
If the flood detector signals an alarm remove it from the affected area until the carpet/flooring is thoroughly dried. Dry the flood 
detector to prevent corrosion of the brass studs. Note: if the flood detector is frequently activated by water on the floor then it 
may be necessary to relocate the device away from the cause of the alarm.  
 
Battery Life 
 
The flood detector battery is checked once a day, if the voltage falls and stays below a preset level for 7 consecutive days a low 
battery alert is automatically transmitted. Once a low battery call is received the flood detector should be replaced within 7 days.  
Flood detectors must be returned to Tynetec/Aidcall for battery replacement. 
 
Detailed information on battery management for all Tynetec/Aidcall products is available ‐ request Doc No. FM0630.  
 
 
 
 
 
Doc No. FM0458 issue E   Page 1  
169MHz Telecare Devices 
Flood Detector 
 
 
 
 
Compatible with Reach at‐home alarms, Advent xt warden call,  
Altec Response and Touchsafe Pro Nursecall systems 
Moisture bridge sensor 
Activated LED indicator 
Supplied with mounting bracket 
Low battery warning 
Dimensions: 50 x 95 x 18 mm (HxWxD) 
Weight: 36 grams 
Product Code: ZXT424 
 
 
 
 
 
 
Tynetec and Aidcall are business units of Legrand Electric Ltd
Unit 10 Cowley Road, Blyth Riverside Business Park, Blyth 
Northumberland, NE24 5TF. Tel: 01670 352 371 Fax: 01670 362 807 
Email: sales@tynetec.co.uk  Web: www.tynetec.co.uk
BRIDGE THE 2 BRASS 
STUDS WITH A DAMP 
CLOTH TO ACTIVATE 
THE RED "ACTIVATED" 
LIGHT WILL FLASH 
FOR ABOUT 8 SECONDS 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZXT424 and is the answer not in the manual?

Questions and answers

Summary of Contents for Tynetec ZXT424

  • Page 1   Installation     It is easier to test and learn the flood detector before fixing – see above.    When fixing; always ensure the 2 brass studs are touching the floor.    Select the best location, then fix to the skirting board with the single screw through   the hole in the right angle bracket.      If using the self adhesive pad; select a location where the skirting board is clean and dry.  Stick the adhesive pad to the rear of right angle bracket then press the detector firmly   to the skirting board ensuring it is stuck securely.     Flood Alarms    If the flood detector signals an alarm remove it from the affected area until the carpet/flooring is thoroughly dried. Dry the flood  detector to prevent corrosion of the brass studs. Note: if the flood detector is frequently activated by water on the floor then it  may be necessary to relocate the device away from the cause of the alarm.     Battery Life    The flood detector battery is checked once a day, if the voltage falls and stays below a preset level for 7 consecutive days a low  battery alert is automatically transmitted. Once a low battery call is received the flood detector should be replaced within 7 days.   Flood detectors must be returned to Tynetec/Aidcall for battery replacement.    Detailed information on battery management for all Tynetec/Aidcall products is available ‐ request Doc No. FM0630.         Tynetec and Aidcall are business units of Legrand Electric Ltd   Unit 10 Cowley Road, Blyth Riverside Business Park, Blyth    Northumberland, NE24 5TF. Tel: 01670 352 371 Fax: 01670 362 807  Email: sales@tynetec.co.uk  Web: www.tynetec.co.uk Doc No. FM0458 issue E   Page 1  ...
  • Page 2 Registering a Flood Detector onto a Reach at‐home alarm unit    1. Put the Reach unit into radio device learn mode…                                                     “Trigger    Press and HOLD the GREEN  button on the Reach unit.  Radio      Device” When the front light FLASHES FAST GREEN release the     button and the Reach will announce “Trigger Radio Device”.     You now have 1 minute to activate the flood detector.      ...
  • Page 3 Registering a Flood Detector onto an Advent xt warden call system    1. Put the Advent xt system into radio device learn mode…                                                       “Ready”   Using the Manager’s DECT telephone;        Press the LINE key and wait for the “Ready” prompt.      Enter 5 0 0 0 followed by the  key.               ...
  • Page 4 Registering a Flood Detector onto an Altec Response local carer alarm unit    1. Put the Altec Response unit into radio device learn mode…                                          tynetec               Press ENTER to activate the wake‐up display then ENTER again to display     the main menu.      Press ENTER to select  Radio Devices          Press ENTER to select  Learn Device           ...
  • Page 5                       2. Enter the big button ID…  The 8 digit ID is printed on a label on the underside of the flood detector.         Note: this ID will always start with 80xxxxxx.          Touch the Add Telecare Device box then use the on‐screen keypad to enter the ID.   ZXT424               W64317              Ser: 09158334    MC  Hint: enter a zone in the Filter box to narrow the search for the room (see below).   ID: 80042241      EE0750 V1.07A      Select the users Call Point ID from the Room pull‐down list box then press Save. ...

Table of Contents