Vent Pipe Starter Adaptors - Viessmann Vitodens 100-W WB1A-24 Installation Instructions Manual

Venting system, wb1a/wb2 series, with preinstalled vent pipe adaptor
Table of Contents

Advertisement

Vent Pipe Starter Adaptors

Parallel vent pipe starter adaptors
for WB1A 8-24, 8-30
Flue
Air
e
a
Fig. 38
Legend
Air intake, max. insertion 2½" /
64mm (use sheet metal screws to
hold in place)
Viessmann parallel adaptor
CPVC slip joint starter adaptor
a
3" / 76mm
b
3¼" / 83mm
c
7" / 178mm
d
approx. 10¾" / 271mm
e
4¾" / 120mm
Parallel vent pipe starter adaptors
for WB2 6-24C, 6-24, 8-32
a
a
d
c
b
Fig. 39
Legend
Air intake, max. insertion 2½" /
64mm (use sheet metal screws to
hold in place)
Viessmann parallel adaptor
CPVC slip joint starter adaptor
a
3" / 76mm
b
2¾" / 70mm
c
7" / 178mm
d
approx. 9
e
4¾" / 120mm
Direct Venting (Two-pipe System)
Flue
Air
e
a
d
c
b
3
/
" / 237mm
8
Parallel vent pipe starter adaptors
for WB2 11-44, 15-60
Flue
Air
e
a
Fig. 40
Legend
Air intake, max. insertion 2½" /
64mm (use sheet metal screws to
hold in place)
Viessmann parallel adaptor
CPVC slip joint starter adaptor
a
4" / 100mm
1
b
5
/
" / 130mm
8
3
c
9
/
" / 237mm
8
d
approx.12" / 305mm
e
5½" / 140mm
a
d
c
b
49