OIL CHANGE PROCEDURES:
Periodic Maintenance of your engine oil should be performed after each 40 hours of use of
your Power Equipment Product. Check your engine oil level prior to each use.
1. Start your engine and let it warm up to get the oil warm and thinner. Turn the ignition switch
to the "STOP" position.
2. Remove the Right Access Cover.
3. Remove the oil cap/dipstick by turning counter clockwise.
USE CAUTION: THE OIL MAY BE HOT.
4. Drain the engine oil using the provided Oil
Drain Tube Extension by screwing the tube
extension onto the oil fill socket. Tip the unit
to the oil drain side to drain the used oil into an
approved receptacle and discard in accordance
with all Federal and State Regulations. Never
dump the used engine oil on the ground or into
drains, only discard in an approved manner.
Check with your local authorities to determine
the regulations in your area.
WARNING! AVOID SPLASHING OF HOT OIL;
IT CAN BURN YOU AND CAUSE SEVERE INJURY.
5. After oil is completely drained, replace dipstick plug and tighten with appropriate tools.
Replace oil with the proper oil for your product. Refer to the Pre- Operating Instruction:
Generator Setup section for exact fill requirements. Always use your dipstick to check the oil
level and only fill to the full mark on the dipstick. Never overfill the engine as this can cause
damage to the unit and void warranty.
6. Replace the dipstick/oil cap on the engine.
7. Replace Right Access Cover.
8. Shake generator to ensure the float in the Oil Alert System is free.
PROPER MAINTENANCE OF THE UNIT WILL INCREASE THE LIFE OF
YOUR PRODUCT. THE OIL MUST BE CHANGED ON A
REGULAR BASIS FOR PROPER OPERATION, AND RELIABILITY AND
TO ALSO MAINTAIN THE WARRANTY ON THIS PRODUCT.
32
Operating Instructions
MAINTENANCE
BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938
& Owner's Manual