Alarm Code
Description
Er34
Minimum flow of the flow sensor
Er35
Excessive flow of the flow sensor
Er39
Flow sensor broken
Er41
The primary air flow is insufficient during the check of the boiler
Er42
The primary air flow is high
Er47
Auger Encoder Error: the encoder of the auger does not receive signal
Er48
Auger Encoder Error: the speed regulation of the auger is not possible
Er52
Er52 IO module error I2C
Maintenance Error: it signals that operating hours set have been reached (1200 hours). You need to call the
Mant
technical assistance.
Besides the failure codes, the stove can show the following messages that do not block its operation:
MESSAGE
Prob
Anomaly on the probes control in check-up.
Service
This message means that the operating hours have been reached (1200). It is necessary to call the technical assistance
service.
Block Ignition
This message appears when the system has not been turned off manually during the Ignition phase (after the preload): the
system will turn off when it works at full capacity.
Cleaning on
Doing a periodic cleaning. Only shown in pellet mode.
Link Error
Fail of communication between the card and the display
11. SERVICING AND CARE
The maintenance operations guarantee a proper operation of the product over its lifetime. Not making these maintenance operations will
affect the safety of the product.
11.1.
BURNER CLEANING
In the Hydrobox and Hydrotex models, even though the burner cleaning is automatic, it is necessary to carry out a weekly cleaning.
-
Use a vacuum to clean the ashes in the burner.
-
Remove the burner from its place and unblock the holes.
-
Hoover the ashes which is inside the burner housing.
In the case of model Hydroconfort, as it has an automatic cleaning system, the burner cleaning must be carried out when it is observed that
the holes in the base are obstructed and do not allow the passage of the oxygen for a correct combustion.
11.2.
CLEANING THE ASH PAN
The ash pan should be emptied when necessary. The boiler should not be operated without having
the ash pan in position. In the event of using olive stone as fuel, the amount of ashes will be higher
than those produced by pellet. In this case the ash pan cleaning should be done more frequently.
In the Hydroconfort model there is a capacity viewer, in case you notice that the level is very high, it is
necessary to proceed with the emptying of the ashes.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
DESCRIPTION
62
HYDROBOX, HYDROTEX AND HYDROCONFORT

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HYDROBOX and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

HydroconfortHydrotex

Table of Contents

Save PDF