Marport is a division of Airmar Technology Corporation. Disclaimer Marport endeavour to ensure that all information in this document is correct and fairly stated, but does not accept liability for any errors or omissions.
M3 System | V2 | Introduction and Presentation Introduction and Presentation Tip: Click Marport logo at the bottom of pages to come back to the table of contents. Introduction Among Marport’s receivers, the M3 is specifically designed for smaller vessels.
Product installation and use Install and use this product in accordance with this user manual. Incorrect use of the product may cause damage to the components or void the warranty. Only qualified Marport dealers can do installation and maintenance interventions.
M3 System | V2 | Introduction and Presentation Equipment List Below are the hardware and software required to install a M3 system. Box 1 and 2 contain the minimum hardware needed to install the system. Box 1: Receiver (M3REC) • 1 M3 receiver •...
M3 System | V2 | Introduction and Presentation Software Software Application Name Definition Marport validated MacOS Operating system on computer VMware Fusion Virtual machine software, necessary to run processor virtual machine. Scala Marport software application collecting, processing, storing and displaying data received from sensors, sounders and other connected devices.
M3 System | V2 | Introduction and Presentation Installation Steps Tip: Click an installation step to jump directly to the corresponding section. | 11...
When you switch on the Mac for the first time, you need to enter setup details. Procedure 1. A setup assistant appears when switching on the computer for the first time. Follow the instructions. 2. From Create a Computer Account, you can use marport for full name, account name and password. Disabling Automatic Updates Procedure 1.
M3 System | V2 | Computer Configuration Disabling Sleeping Mode Procedure 1. From the top left corner of the screen, click Apple Menu > System Preferences > Energy Saver. 2. From Turn display off after, drag the handle to Never. 3. Unselect Enable Power Nap and Put hard disks to sleep when possible.
M3 System | V2 | Computer Configuration 4. Select Allow apps downloaded from: Anywhere. 5. If you are under OS X Sierra, Anywhere option may not be displayed by default. To display Anywhere: a) From the top right corner of the screen, click the magnifying glass and type Terminal.
Page 15
M3 System | V2 | Computer Configuration 2. From the tab Screen Saver, select Start after: Never. 3. From the tab Desktop, click Folders, then the add icon from the bottom left corner. 4. Select the Downloads folder and click Choose.
5. From Downloads, select Marport wallpaper (See Downloading Software Applications on page 18 to know where to find Marport wallpaper). Adding a Virtual Keyboard If you have no keyboard, you can add a virtual keyboard to the screen and type words using the mouse.
M3 System | V2 | Computer Configuration 4. From the top right corner of the screen, click the little flag corresponding to the keyboard language preferences, then select Show Keyboard Viewer. Results A virtual keyboard is displayed on the screen. You can change its size by dragging its corners.
M3 System | V2 | Computer Configuration Installing Software Applications Downloading Software Applications Some software applications required to configure and use the M3 system are already installed on the computer. Marport offices need to download from a Marport FTP server and from the DealerWeb additional applications.
M3 System | V2 | Computer Configuration c) Click Download in front of the latest firmware version with a Release diffusion status. Results The files you downloaded from the DealerWeb are saved in your Downloads folder. (See Installing Scala and Scala Replay...
Page 20
M3 System | V2 | Computer Configuration Note: If not using a Marport supplied Mac or if there is no sticker, please buy a Fusion PRO license. 3. If the following window appears, click Cancel. VMware Fusion is installed on the computer.
M3 System | V2 | Computer Configuration c) From the USB & Bluetooth window, from the bottom of the window select Connect to your Mac. Installing Mozilla Firefox About this task Important: Compatible versions with the system: versions 22 to 51.
M3 System | V2 | Computer Configuration 2. When the following window appears, drag Firefox icon as indicated. Results Firefox is now installed on the computer and accessible via the Launchpad . Drag its icon to the Dock if you want a quicker access.
M3 System | V2 | Computer Configuration Procedure 1. Double-click the installation zip file. 2. Click the *.dmg file. 3. From the installation panel, double-click Sentinel Runtime.pkg. If a warning appears, click Open again. 4. Follow the installation steps. 5. From the installation window that appears, drag Scala icon to the Applications icon.
Installing Marport Tools Procedure 1. Double-click Marport Tools installation file to unzip it. 2. From MarportTools folder, copy Marport Tools application and paste it in the Applications folder. Marport Tools is now installed on your computer and accessible via the Launchpad Drag its icon to the Dock for a quicker access.
Page 25
M3 System | V2 | Computer Configuration 2. Click the tab Login Items. 3. Click the plus sign under the list, then go in the Applications folder and select Scala. 4. Repeat the procedure for VMware Fusion. Scala and VMware Fusion are added to the list.
What to do next You need to configure the virtual machine network. Sharing System Information Marport offices only: You need to share details about the sytem so that Marport can keep record of systems installed. Procedure 1. Go the the DealerWeb web page: https://dealerweb.marport.fr/Default.aspx.
Once the computer is configured, you can clone its hard drive and then, install the hard drive image on other Mac mini i5 computers for a M3 system, in order to save time for future installations. Refer to Cloning Disks user guide for more information.
M3 System | V2 | Installation Installation Installing the System Procedure 1. Check that you have all the items needed for the installation (See Equipment List page 9) 2. Install the hydrophones and their cables, or find the cables from hydrophones that have already been installed.
M3 System | V2 | Installation M3 Receiver Cabling Cable Connected to 1 Marport junction box Junction box extension cable 2 Ethernet cable PoE injector in Mac mini mounting bracket (OSU power slot) 3 Ground strap Grounded to the ship ground Important: Do not press the button on the receiver.
M3 System | V2 | Installation Mac Mini Cabling Cable Connected to 1 Power cable 100-240V AC power supply* 2 Ethernet cable PoE injector in mounting bracket (computer slot) 3 Thunderbolt to HDMI/VGA/ Monitor 1 and 2 (optional) DVI adapters † + monitor cable...
To know how to install the Ethernet connector to the new cable, refer to the assembly instructions included with the Ethernet connector kit. Configuring Networks This procedure applies only to technicians from Marport offices. Marport technicians need to configure the Ethernet networks so that the receiver and the Mac mini communicate with each other.
Page 32
M3 System | V2 | Installation 3. If not, to change the order click the tooth wheel icon at the bottom of the list and select Set Service Order. Important: The order of the networks is important. If Apple USB Ethernet Adapter is not first in the list, the computer will not connect to the internet.
M3 System | V2 | Installation b) From IP Address enter 192.168.44.100, and from Router enter 192.168.44.1. Configuring Virtual Machine Network Before you begin To configure the virtual machine network, you need to create a virtual network. You need to have a registered key license for VMware Fusion Pro.
Page 34
M3 System | V2 | Installation f) Click Apply. 3. From the M3-Processor window, click the tool icon. 4. From M3-Processor Settings, click Network Adapter. | 34...
Page 35
M3 System | V2 | Installation 5. Select the virtual network you created: vmnet2. 6. Check that there is a green LED next to the network name and that the IP address is 192.168.10.0. 7. Close the window. 8. From the M3-Processor window, click the tool icon again.
Page 36
M3 System | V2 | Installation 11. Check that there is a green LED next to the network name and that the IP address is 192.168.44.100. If not, click System Preferences at the bottom of the window to manually change the IP address.
Page 37
If you have an error message or red crosses, see the Troubleshooting page 70 for more information. 18. From the M3-Processor window, check that the you see the prompt marport: login: Note: The prompt ending by failed does not impact the correct functioning, you can ignore it.
M3 System | V2 | Installation Installing Hydrophones Types of Marport Hydrophones Typical Product Name Use case Bandwidth current reference consumption NC-1-05 Passive wideband 33-60 0.0 mA • Vessel with very low hydrophone (no level of noise. preamplifier) • For positioning systems...
M3 System | V2 | Installation Hydrophone Cablings Passive Hydrophone We recommend the following wirings for the installation of the wideband passive hydrophone NC-1-05. Beamwidth: • 55°x 55° : only connect cell with black + green wires • 55° x 35°: connect both cells For temperature connection to Mx, use direct connection NTC to H1 and/or H2.
Page 40
M3 System | V2 | Installation The notches are activated by two wire straps that come with the pre-amplifier. Preferably install the pre-amplifier as close as possible to the hydrophone and put the junction box as close as possible to the receiver.
Page 41
M3 System | V2 | Installation Configuration 2 • Gain: Low • Notch filter 38kHz: On • Notch filter 50kHz: On | 41...
Page 42
M3 System | V2 | Installation Configuration 3 • Gain: Low • Notch filter 38kHz: Off • Notch filter 50kHz: Off | 42...
M3 System | V2 | Installation Active Hydrophone We recommend the following wirings for the installation of the active hydrophone NC-1-04. For temperature connection to Mx, use direct connection NTC to H1 and/or H2. For connection to H3 on the Mx unit, use the external NMEA converter box.
M3 System | V2 | Installation Active Wideband Hydrophone We recommend the following wirings for the installation of the wideband active shielded hydrophone NC-1-06. About The pre-amplifier inside the hydrophone can be configured depending on the hydrophone wiring to the junction box. There are 4 different configurations:...
Page 45
M3 System | V2 | Installation Configuration 2 First generation 46-127-X Second generation 46-138-X 38kHz and 50kHz filters activated / Gain 38kHz filter activated / Gain Low This configuration is recommended for seine fishing, trawling in shallow water or close to surface.
Page 46
M3 System | V2 | Installation Configuration 3 First generation 46-127-X Second generation 46-138-X 38kHz filter activated / Gain High 38kHz and 50kHz filters activated / Gain High | 46...
Page 47
M3 System | V2 | Installation Configuration 4 First generation 46-127-X Second generation 46-138-X No Filters / Gain High 50kHz filter activated / Gain High | 47...
We recommend the following wirings to connect a Scanmar hydrophone to a Marport system. Scanmar hydrophones can be used with Marport receivers. They will show a lower current (5.5mA instead of 8-9mA). You need to connect the junction box to the third hydrophone connector (H3) on the receiver.
We recommend the following wirings to connect Simrad PI hydrophone to a Marport system. On Scala, Simrad PI hydrophone can be added to the receiver as an active Marport hydrophone (NC-1-02/04). It is recommended to put capacitors of 1.5 μF/ 63V on the +12V and -12V cables to reduce noise.
M3 System | V2 | Installation Furuno Passive Hydrophone We recommend the following wirings to connect Furuno passive hydrophones to a Marport system. Furuno hydrophones have three different bandwidths: • 31.5-34.5kHz • 38-42kHz • 47.5-52.5kHz | 50...
M3 System | V2 | Installation Understanding Receiver LEDs Boot sequence When the receiver restarts, the hydrophone and PoE LEDs light up according to a specific sequence. At the end of the sequence: • LEDs are off if no hydrophone is configured.
M3 System | V2 | Installation Installing ShipModul MiniPlex Multiplexer (Optional) You can use a ShipModul MiniPlex multiplexer to receive simultaneously NMEA data from devices such as GPS, compass or warp length sensor module and display them in Scala. Important: ShipModul multiplexer cannot read NMEA messages longer than the standard maximum length (82 characters), nor other format messages longer than 61 characters, nor Marelec messages.
M3 System | V2 | Installation NMEA Multiplexer Cabling You can connect ShipModul MiniPlex-3E-N2K or Miniplex-3E NMEA multiplexers in two different ways, depending on whether you have a network with DHCP server or not. Wired Ethernet network Connect the multiplexer according to the following schema if: •...
Page 54
M3 System | V2 | Installation WiFi connection / No wired Ethernet network Connect the multiplexer according to the following schema if: • you connect to the internet via WiFi, • or you do not have a wired Ethernet network.
M3 System | V2 | Installation Detecting the Multiplexer You need to detect the multiplexer on the network to be able to use it. Wiring and configuration change according to your type of network installation. Before you begin • Scala must be closed.
Page 56
M3 System | V2 | Installation b) Check that the USB/Thunderbolt to Ethernet adapter is on top of the network list. If not, click the tooth wheel icon at the bottom of the list, select Set Service Order and drag USB/Thunderbolt to Ethernet adapter to the top.
M3 System | V2 | Installation WiFi Connection / No Wired Ethernet Network About this task Do this procedure if: • You have a wireless internet connection • Or you have no wired Ethernet network Procedure 1. If you are connected to a WiFi network, turn off the WiFi on your computer.
Page 58
M3 System | V2 | Installation e) From Router, enter the same numbers as for the IP address. f) Click Apply. 4. Open MPX-Config3 and from the toolbar click Tools > MiniPlex-3E > Search. The multiplexer is displayed. Its IP address is also an auto-IP address that you need to change.
M3 System | V2 | Installation c) From Gateway IP, enter the USB to Ethernet adapter IP address: 192.168.70.1. d) Click OK. From the part MiniPlex Connection, the Host IP address is updated. 7. From MiniPlex Connection, click Connect. If you have connected and correctly configured the baud speed of the device outputting NMEA data, you should see incoming NMEA messages.
Page 60
M3 System | V2 | Installation The multiplexer is displayed. You can see its IP address (192.168.70.2). 3. Click Apple Menu > System Preferences > Network. 4. Check that the USB/Thunderbolt to Ethernet adapter is on top of the network list. If not, click the tooth wheel icon at the bottom of the list, select Set Service Order and drag USB/Thunderbolt to Ethernet adapter to the top.
M3 System | V2 | Installation 6. From MPX-Config3, click Tools > MiniPlex-35 > Network Setup. a) from Gateway IP, enter the IP address of the USB/Thunderbolt to Ethernet adapter (in this example 192.168.70.4). b) Click OK. 7. From MiniPlex Connection, click Connect.
M3 System | V2 | Installation c) Click OK. Wait for the update process to complete (approx. 10 sec.). 3. You can now have access to the multiplexer settings through Network Settings dialog box. Configuring Inputs You can configure the NMEA inputs of the multiplexer from MPX-Config3 software.
Page 63
M3 System | V2 | Installation The console will output the following messages: You can see the talker IDs AA and BB at the beginning of the NMEA sentences. On the multiplexer, the LED NMEA0183 blinks green. NMEA2000 Example Device 3 is a WeatherStation WX220 from Airmar on NMEA 2000.
M3 System | V2 | Installation Other formats If your device outputs messages in other formats than NMEA, for example Rapp Marine or non-standard NMEA messages beginning by @: from Input Mode, select Plain Text. If you do not select Plain Text, messages will not be received by the multiplexer.
Page 65
M3 System | V2 | Installation 6. From the Sensor Data section of the control panels, under the tab NMEA, check the activity of data received. If you gave talker IDs to the devices you configured on MPX-Config3, you can see that each device is identified by its talker ID (AA, BB and CC).
M3 System | V2 | Servicing and Maintenance Servicing and Maintenance Interference Check Spectrum Analyzer Display The following picture explains the main parts of the spectrum analyzer on Scala. Checking Noise Interference You can use the spectrum analyzer to check the noise level of the hydrophones and check if there are no interference.
Page 67
M3 System | V2 | Servicing and Maintenance 3. From the top right corner of the screen, click Spectrum. 4. From the top left corner of the screen, click Start Spectrum. 5. Select the hydrophone you want to test. Only the hydrophones that are switched on are displayed.
M3 System | V2 | Servicing and Maintenance 12. When you have enough data, click Stop Spectrum. Updating the Processor and Receiver This procedure applies only to technicians from Marport offices. You can update the Processor and Receiver firmware when new versions are available. Procedure 1.
Page 69
10. Right-click the new firmware and select Update Equipment Software. 11. Wait for the update to be complete. 12. Reboot the receiver to complete the update: from Marport Tools toolbar, click Marport > Discovery > Reboot Equipment. 13. To refresh data displayed in Marport Tools, from Marport Tools toolbar, click Marport >...
M3 System | V2 | Servicing and Maintenance Results The receiver is updated. Troubleshooting Hydrophone Modules on Receiver Page Are Disconnected The receiver page is displayed the following way: Or you have the following error message: Possible cause The computer cannot connect to the receiver. There might be an issue with the network or the virtual machine.
Page 71
M3 System | V2 | Servicing and Maintenance Procedure 1. Check connections and refresh the page. 2. If the system still does not work, restart the computer. 3. If the system still does not work, follow the instructions below. 4. Open a terminal to check the M3 connection.
Page 72
M3 System | V2 | Servicing and Maintenance 9. Unselect Connect Network Adapter and select Autodetect from the list. 10. Restart the virtual machine: from VMware Fusion toolbar, click Virtual Machine > Restart. 11. Reconfigure correctly the Ethernet network adapter 2:...
M3 System | V2 | Servicing and Maintenance Error Message on Receiver Page On the receiver page, you have the following error message: Possible cause The M3 receiver is not connected to the Mac mini. Procedure 1. Restart the computer.
M3 System | V2 | Servicing and Maintenance Receiver Page is Empty You do not receive sensor data anymore on Scala, and the receiver page looks like one of the image below: Possible cause The virtual machine (VMware Fusion) is off.
M3 System | V2 | Servicing and Maintenance 2. When the computer is on, from the Dock, click VMware Fusion icon and check that there are command lines in the M3-Processor window. Note: The prompt ending by failed does not impact the correct functioning, you can ignore it.
Page 76
M3 System | V2 | Servicing and Maintenance Possible Cause There is a communication issue between the M3-Processor and the receiver. Procedure 1. From the left side of the receiver page, click Hydrophones. 2. From Rx/Tx, click the drop-down menu and select again the correct hydrophone configuration (even if it is already selected).
M3 System | V2 | Servicing and Maintenance VMware Fusion Pop-Up Message A VMware Fusion message appears when adding a new USB key. Possible cause This message is due to the virtual machine (VMware Fusion) installed on the computer. Procedure 1.
M3 System | V2 | Servicing and Maintenance Giving Remote Access to the Computer If you have an issue with the system, you may need to give remote access to the computer to the support team with TeamViewer software. Before you begin You need to have access to a good internet connection.
M3 System | V2 | Servicing and Maintenance Support Contact You can contact your local dealer if you need maintenance on your Marport products. You can also ask us at the following contact details: FRANCE ICELAND Marport France SAS Marport EHF...
M3 System | V2 | Appendix Appendix Appendix A: Frequency Plan When the system is installed, you can add sensors to it. It is important to carefully plan the setup of your sensors before adding them to the system. You can create a table with a list of frequencies and complete it when you add sensors.
Page 81
M3 System | V2 | Appendix Boat Codes This list shows the standard frequencies for PRP telegrams. When you configure boat codes, make sure to respect the correct interval between frequencies (see table above). | 81...
Need help?
Do you have a question about the M3 System and is the answer not in the manual?