11.2.4 Open circuit or short circuit of temperature sensor diagnosis and solution(E5)
Error Code
Malfunction decision
conditions
Supposed causes
Trouble shooting:
Check the connection
between temperature
sensor and PCB.
Yes
Measure the resistance
value of the sensor
Yes
Replace indoor or outdoor
main PCB
42
E60/E61/E53/E52/E54
If the sampling voltage is lower than 0.06V or higher than 4.94V,
the LED will display the failure.
Wiring mistake
Sensor faulty
PCB faulty
No
No
Correct the connection
Repalce the sensor
DM16-01.01.23en