Midea MSEAAU-09HRFN1(SB) Service Manual page 33

Kids star inverter series, indoor/outdoor units
Table of Contents

Advertisement

DM16-01.01.23en
Kids Star Inverter
10.4.3.5 Evaporator coil temperature protection
Off
Decrease
Hold
Resume
When evaporator temperature temp. is more than the setting protection value, the compressor will
stop.
10.4.4 Auto-mode
This mode can be chosen with remote controller and the setting temperature can be changed between
17°C~30°C
In auto mode, the machine will choose cooling, heating or fan-only mode according to T1,TS and T4.
Indoor fan will run at auto fan of the relevant mode.
The louver operates same as in relevant mode.
If the machine switches mode between heating and cooling, the compressor will keep stopping for
certain time and then choose mode according to T1,TS and T4.
If the setting temperature is modified, the machine will choose running function again.
10.4.5 Forced operation function
Forced cooling mode:
The compressor and outdoor fan keep running and the indoor fan runs at rated cooling fan speed.
After running for 30 minutes, AC will turn to auto mode with 24℃ setting temperature.
Forced auto mode:
The action of forced auto mode is the same as normal auto mode with 24℃ setting temperature.
When AC receives signals, such as switch on, switch off, mode setting, fan speed setting, Temp.
setting, it will quit the forced operation.
Service manual
33