10.3 Main Protection

10.3.1 Three minutes delay at restart for compressor
st
Less than 1 minute delay for the 1
time start-up and 3 minutes delay for others.
10.3.2 Temperature protection of compressor top
The unit will stop working when the compressor top temp. protector cut off, and will restart after the
compressor top temp. protector restart.
10.3.3 Temperature protection of compressor discharge
Compressor discharge temp. TP>115℃ for 9s, compressor stops.
10.3.4 Fan speed is out of control
When indoor fan speed keeps too low (300RPM) or too high (1500RPM) for certain time, the unit will
stop and the LED will display the failure
10.3.5 Inverter module protection
The Inverter module has a protection function about current, voltage and temperature. If these
protections happen, the corresponding code will display on indoor unit and the unit will stop working.
10.3.6 Indoor fan delayed open function
When the unit starts up, the louver will be active immediately and the indoor fan will open later.
If the unit runs in heating mode, the indoor fan will be also controlled by anti-cold wind function.
10.3.7 Compressor preheating functions
Preheating permitting condition:
When T4(outdoor ambient temperature)<3°C, the preheating function will be activated.
10.3.8 Sensor protection at open circuit and breaking disconnection.
When there's only one temperature sensor in malfunction , the air conditioner will keep working but
show the error code, in case of any emergency use.
When there's more than one temperature sensor in malfunction, the air conditioner will stop working.
10.3.9 Refrigerant leakage detection
It can better prevent the compressor being damaged by refrigerant leakage or compressor overload.