19
Condenser pipe temp. of 1# indoor unit
20
Condenser pipe temp. of 2# indoor unit
21
Reserved
22
1# Indoor unit capacity demand code
23
2# Indoor unit capacity demand code
24
Reserved
Electrical Control System
General:1, Twins:2
If the temp. is lower than 0 degree, the digital display tube will
show "0".If the temp. is higher than 70 degree, the digital
display tube will show "70". If the capacity demand is 0, , the
digital display tube will show "0. If the indoor unit is not
connected, the digital display tube will show: "――"(heating
T2,cooling T2B)
Actual data*HP*10
If capacity demand code is higher than 99, the digital display
tube will show single digit and tens digit. (For example, the
digital display tube show "5.0",it means the capacity demand
is 15. the digital display tube show "60",it means the capacity
demand is 6.0). If the indoor unit is not connected, the digital
display tube will show: "――"
Electrical Control Function